acec hcx63 Manuel D’Utilisation

Page de 11
Part 1
a
INSTALLATION INSTRUCTIONS
This canopy hood is designed to be fixed to any rigid vertical surface, over a cooking area, and can be
used either in the extraction (ducted to the outside) or in the recirculation mode (internal recycling). In
consideration of the difficulties of installation and of the weight of the hood, the installation work must
be undertaken by a qualified and competent person. The manufacturer disclaims all liability for any
damage or injury caused as a result of not following the instructions for installation contained in the
following text.
2 -
COMPONENTS.
The cooker hood is made up of the following components (fig. 1)
2.1 -
A canopy C, including controls, worktop illumination and fan unit
2.2 -
No. l telescopic chimney stack formed by:
- No. l U-shaped upper section S
- No. l U-shaped lower section I
- No. 2 recirculation venting grilles G
2.3 -
No. l recirculation ducting spigot F
2.4 -
No. l extraction ducting spigot A Ø 120/100 mm
2.5 -
No. l additional recirculation spigot P (see paragraph 4).
2.6 -
No. l fixing kit including:
- No. 3 wall brackets 1, 2, 3
- rawl plugs and screws
- fixing documentation
2.7 -
No. l splashback B (available on request).
3 -
SAFETY WARNINGS.
3.1 -
When used in the extraction mode the cooker hood ducting must not be connected to a central
heating flue, radiator or a water heater.
3.2 -
Before connection to the mains supply ensure that the mains voltage corres-ponds with the
voltage on the rating plate inside the hood.
3.3 -
Connect the hood to the mains supply via a double pole switch which has 3mm clearance
between the contacts.
3.4 -
Ensure that the electric plant allows the hood to be correctly earthed.
3.5 -
When installed, the hood must be positioned at least 65 cm above a cooking appliance.
3.6 -
Never do flambé cooking under this cooker hood.
3.7 -
Never leave frying pans unattended during use as overheated fats and oi1s may catch fire.
3.8 -
Before carrying out any kind of maintenance or cleaning, disconnect the hood from the mains
supply.
3.9 -
If the room where the cooker hood is to be used contains other non-electric appliances (such as
gas appliances) ensure that there is an adequate supply of air to the room.
4 -
INSTALLATION.
For easy installation proceed as follows:
4.1 -
Fix the wall brackets (and the splashback, if available).
4.2 -
Fix the canopy.
4.3 -
Connect the hood to the mains supply and ensure that it works properly.
4.4 -
Set the hood for recirculation or extraction.
4.5 -