Elevator Control
Elevator control is one particular application of the IOM ACTWinPro allows
programming of users, permitting them access to different floors in an elevator lift
shaft at different times.
The outputs on the IOM are wired into an elevator controller. Up to 32 floors maybe
controlled from a single ACT3000/2000. However controllers maybe networked
giving control of more floors.
programming of users, permitting them access to different floors in an elevator lift
shaft at different times.
The outputs on the IOM are wired into an elevator controller. Up to 32 floors maybe
controlled from a single ACT3000/2000. However controllers maybe networked
giving control of more floors.
Step 1
.
The first step is to select the Elevator Floor option
for the output. This
means that this relay acts as an Elevator Floor. Notice that all the other options are
greyed-out.
greyed-out.
Step 2.
Click on the Floor Groups option under the Database drop-down box.
Click the New icon
to generate a new Floor Group in the database. Select a
controller that the Floor Group will belong to and assign the Floor Group a name.
Finally, click the Accept icon
.
Step 3
.
All the outputs that are assigned the Elevator Floor option AND belong to the selected
controller will appear in the Floors not in Group box on the left. Use the
button
to move the desired Floors into the group. Click the Accept icon
.