C
ONFIGURING
 D3LX A
LARMS
Use this procedure to set alarm indicators for equipment, optical 
facilities, and DS3 facilities groups for each D3LX CO module. You 
can select CRITICAL (CR), MAJOR (MJ), MINOR (MN), EVENT 
(EV), or NOT RPTD (not reported) for each field.
Setting Alarm Levels
1
From the Main menu, select
 1. Alarms
2
From the Alarms menu, select
 6. Set Alarms Levels
3
From the Set Alarm Levels menu, select 
7. Set D3LX Alarm Levels
The D3LX CO Alarm Levels screen appears as shown in 
4
In the Group toggle field, use 
 to select the group number (1-7). 
5
From the Equipment AlarmsOptical Facility Alarms, and DS3 Facility Alarms fields, select CRITICAL 
(CR), MAJOR (MJ), MINOR (MN), EVENT (EV), or NOT RPTD (not reported) for each field. Default 
alarm levels are shown in 
. Assign the selections by pressing 
 Housekeeping Labels 
1 and 2
Input
Enter up to 8 
alphanumeric 
characters.
Enter the remote housekeeping alarm label you 
want for each field; the fields can be edited to 
create customized labels. When a 
housekeeping alarm occurs, for example, door 
ajar, water on the floor, or fire alarm, the name 
assigned is displayed in the condition column 
of the Alarm History and Active Alarms screens.
SCU V3.7 = Blank
* This field shows as N/A if D3RCAM is not installed at the Four-Position Remote Terminal Cabinet or Two-Position QLX Remote BNC 
Chassis.
Abbreviations of the alarm field options (except NOT RPTD) appear in the Active Alarms and 
Alarm History screens. The option you select for a particular type of alarm determines whether 
you will be notified when that type alarm occurs: critical, major, and minor alarms are audible 
and visual notifications, events are system actions without audible and visual notifications, and 
not reported alarms do not require notification. 
Table 5.
D3LX CO Configuration Fields–SCU V3.7 or later (Continued)
Field Name
Type
Options
Description
Default
1. Alarms
6. Set Alarm Levels
7. Set D3LX Alarm Levels
SPACEBAR
ENTER