The HiGain HDU-439 mini doubler can also be installed along with the 
HDU-409 micro doubler in the same enclosure. Assign a thermal weight of 
1.5 HDU-409 for every HDU-439 and round down to the nearest whole 
number. This results in one of the following thermal relationships:
a) 1.5 (HDU-409) = 1 (HDU-439)
b) 1 (HDU-409) = 2/3 (HDU-439)
For example, if an AT&T 819 case has only 10 HDU-409 doublers leaving 
room for four more HDU-409 doublers, the number of HDU-439 doublers 
that can be allotted to these 4 slots is determined by using (b) as follows:
4 (HDU-409) = (4) (2/3) (HDU-439)
4 (HDU-409) = 2.66 (HDU-439) = 2 (HDU-439)
Similarly the number of HDU-439 doublers that can be allotted to 6 empty 
HDU-409 slots is:
6 (HDU-409) = (6) (2/3) (HDU-439) = 3 (HDU-439)
M
ICRO
 D
OUBLER
 C
APACITY
 D
EPLOYMENT
 
R
ULES
The deployment rules for micro doubler capacity are summarized below:
1
Use 
 for indoor enclosures.
2
Use 
 for outdoor enclosures with full 
solar load for ambient temperatures up to 115°F maximum.
3
The capacities shown in 
 can be increased to all odd or even slots 
(where applicable) for non-solar load (shaded or manhole applications). 
The non-adjacency constraint still applies for these increased capacity 
applications. The capacity of the ABACON HDSL 16 enclosure can be 
increased to 16 for non-solar load applications.
When assigning slot locations, make sure there is an empty 
slot between any two adjacent doublers (HDU-409 and 
HDU-439).