ADC H2TU-C-388 Manuel D’Utilisation

Page de 66
152-388-100-02, Issue 2
 
Monitoring System Activity and Performance
H2TU-C-388 List 1
June 6, 2000
 23
3
To initiate a loopdown of all active loopbacks, press the 
 to select LPDN, then press 
 or 
. When prompted with the message: 
Are you sure (Y/N)?
, press 
 to initiate the loopdown or 
 to 
cancel.
Table 8.
Monitor Screen Descriptions
Field 
Description
Active Loopback
An active loopback is indicated on the lower third of the Monitor screen. Available loopbacks are 
indicated by gray text. Se
 for a summary of the HiGain loopback codes.
Alarm type
Indicates type of alarm.
Armed mode
Indicates system is in an armed state for an intelligent repeater loopback command.
Code type
Type of DS1 line coding received or sent (B8ZS or AMI). 
DS1 ES Count
Errored Seconds—The sum of the Errored Seconds-Line (ES-L) and Errored Seconds-Path (ES-P) 
counts detected on the DS1 input over a 24-hour period. Errors included are: DS1 Frame errors, 
BPV, and ESF CRC errors. 
DS1 SES Count
Severely Errored Seconds—The sum of the DS1 Severely Errored Seconds-Line (SES-L) and 
Severely Errored Seconds-Path (SES-P) counts over the last 24 hours. 
DS1 UAS Count
Unavailable Errored Seconds—The number of seconds during which the DS1 input signal was 
absent over a 24-hour period.
Frame type
Type of DS1 framing detected at the input stream (SF, ESF, or UNFR).
HDSL2 ES Count
Errored Seconds—The number of 1-second intervals that contained at least one CRC or LOSW 
error. This value is a running total of the last 24 Hours.
HDSL2 SES Count
Severely Errored Seconds—The number of 1-second intervals that contain at least 50 CRC errors 
or one or more LOSW defects. (An LOSW defect occurs when at least three consecutive HDSL 
frames contain one or more frame bit errors.) This value is a running total of the last 24 hours.
HDSL2 UAS Count
Unavailable Errored Seconds—The number of seconds the HDSL2 loop is unavailable. This occurs 
after 10 contiguous HDSL SES and is retired after 10 contiguous non-SES seconds. This value is 
a running total of the last 24 hours. 
ID 
Circuit identification (ID) number.
LA
Loop Attenuation—Indicates the attenuation of the Overlapped PAM Transmission with 
Interlocking Spectra (OPTIS) pulse from the distant end. The value is related to the loop attenuation 
at 196 kHz and should be kept under 35 dB.
LPF
Line Power Feed—Indicates the HDSL2 line power is on.
M
Margin—The signal-to-noise ratio at all HDSL2 ports, relative to a 10
-7
 Bit Error Rate.
MAL
Margin Alarm—Indicates the margin on HDSL2 loop has dropped below the threshold (0 to 15dB) 
as set by the operator.
PL (or HG)
PL displays when the loopback was initiated by a command embedded in the DS1 data path 
payload (PL). HG displays when the loopback was initiated from a HiGain Generic (HG) front panel 
or by a HiGain maintenance terminal loopback command.
PRM
The sum of the Performance Report Messaging-Near End (PRM-NE) and Performance Report 
Messaging-Far End (PRM-FE) counts.
System Status
The presence or absence of an alarm condition is indicated on the lower right corner of all screens. 
System: OK indicates that there are no alarms present; System: Alarm indicates the presence of 
an alarm. Refer to 
 for detailed 
alarm information.
SPACEBAR
ENTER
N
Y
N