Juniper CBL-PWR-10AC-STR-IT Manuel D’Utilisation

Page de 232
CAUTION:
To maintain agency approvals, use only a properly constructed,
shielded cable.
and
describe the RJ-48 connector pinouts.
Table 30: RJ-48 Connector to RJ-48 Connector (Straight) Pinout for the
Router
Signal
RJ-48 Pin
(Data numbering
form)
RJ-48 Pin (on T1/E1 PIC)
(Data numbering form)
RX, Ring, –
1
1
RX, Tip, +
2
2
TX, Ring, –
4
4
TX, Tip, +
5
5
Shield/Return/Ground
3
3
Shield/Return/Ground
6
6
No connect
No connect
7
No connect
No connect
8
Table 31: RJ-48 Connector to RJ-48 Connector (Crossover) Pinout for the
Router
Signal
RJ-48 Pin
(Data numbering
form)
RJ-48 Pin (on T1/E1 PIC)
(Data numbering form)
RX/Ring/– <––>TX/Ring/–
4
1
RX/Tip/+ <––>TX/Tip/+
5
2
TX/Ring/– <––>RX/Ring/–
1
4
TX/Tip/+ <––>RX/Tip/+
2
5
Shield/Return/Ground
3
3
Shield/Return/Ground
6
6
187
Copyright © 2012, Juniper Networks, Inc.
Appendix F: M7i Cable Connector Pinouts