Nikon COOLPIX 4500 Manuel De Maintenance

Page de 65
VAA11901-R.3579.A
- E4500 -
The contents of inspection standards and tools for E4500
[1] Inspection standard  ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・  R1 to R6
[2] Tools  ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ T1 to T2 
1.  Pyysical stance to measure:
     On the applicable product,its lens shall be set flat and its monitor shall be set to vertically stand up.
2.  Room temperature and constantly controlled humidity:
     25±5℃    Relative humidity:65±20%
3.  Battery to be employed:
       Primary battery:
            Unless otherwise specified,use a Sanyo 2CR5 lithium battery(within four months of manufacture).
            When using various manufactures,conduct the inspection using a Sanyo,Matsushita or Duracell 2CR5 lithium        
            battery.
       Secondary battery:
            Use the dedicated rechargeable battery EN-EL1.
            (Use after it has been fully charged with the dedicated AC adapter EH-53.)
4.  Standard power supply:
     Specified AC power supply EH-53 shall be required.