Chassis
M40 Internet Router Hardware Guide
8
Chassis
The router chassis is a rigid sheet metal structure that houses all the other router hardware 
components (see Figure 1 and Figure 2). The chassis is 19 in. (48 cm) wide and 23.5 in. 
(60 cm) deep. The chassis height of 35 in. (89 cm) enables stacked installation of two M40 
routers in a single floor-to-ceiling rack. The two front- or center-mounting ears (one on each 
side) enable installation into either a front-mount or a center-mount rack. For more 
information, see “Rack Requirements” on page 39.
The chassis includes two electrostatic discharge (ESD) points (banana plug receptacles), one 
front and one rear, as shown in Figure 1 and Figure 2.
Figure 1:  Front View of Chassis
Before removing or installing components of a functioning 
router, attach an ESD strap to one of the ESD points and 
place the other end of the strap around your bare wrist. 
Failure to use an ESD strap could result in damage to the 
router.
The router must be connected to earth ground during 
normal operation. 
Slide guides for FPCs
Craft interface
ESD point
Air filter
Card cage
Backplane
Front rack-mounting ear
Cable managment
system
1002
Center rack-mounting ear