Sony BKP-7933 Manuel D’Utilisation

Page de 56
1-12 (E)
BKP-7933
1-7-2. Linking the RCP Assignment and VE Monitor Selection
Description of Operation
Set the menu as follows when you want to link the RCP assignment with the VE monitor selection.
If this setting is executed, by changing the RCP assignment on the MSU side, the VE monitor that
corresponds to the RCP is automatically switched at the same time.
(Example) When the camera that is controlled by RCP1 is changed from CAM1 to CAM5, the video
signal on the VE monitor in front of RCP1 is switched at the same time from CAM1 to CAM5.
n
The contents that are set on this menu are reflected to the “Setting status of the control system” of the
CNU-700 character display.
1-7. Setting Up
CCU 1
CCU 2
CCU 3
CCU 4
CCU 5
CCU 6
(001) OUT 1
(001)
(DESTINATION No.)
(002) OUT 2
(003) OUT 3
(004) OUT 4
(005) OUT 5
(006) OUT 6
CCU-700A
Digital Video Routing Switcher
BVP-500/700/900 series
PIX
RCP1
RCP-700 series
PIX
RCP2
PIX
RCP3
PIX
RCP4
PIX
RCP5
PIX
RCP6
(SOURCE No.)
SERIAL
OUT
 IN 1
(002)
SERIAL
OUT
 IN 2
(003)
SERIAL
OUT
 IN 3
(004)
SERIAL
OUT
 IN 4
(005)
SERIAL
OUT
 IN 5
(006)
SERIAL
OUT
 IN 6