Location and Functions of Parts and Controls
3
CF card lever
Press the lever to remove the CF card 
from the CF card slot.
4
POWER indicator (green)
When the power is supplied to the 
camera, the camera starts checking the 
system.
If the system is normal, this indicator 
lights up.
If a system error occurs, this indicator 
flashes every second. In this case, 
consult your authorized Sony dealer.
5
Lens
A × 18 optical zoom, auto-focus lens is 
mounted as standard equipment.
6
 (network) port (RJ45)
Connect to the 10BASE-T or 100BASE-
TX network using a network cable 
(UTP, category 5).
7
DC 12 V/AC 24 V (power input) 
terminal
Connect to a 12V DC or 24V AC power 
supply system.
8
T
 (video output) connector 
(BNC type)
Outputs a composite video signal.  
Connect to a composite video input 
connector of a video monitor, VCR, etc.
9
Reset switch
To reset the camera to the factory default 
settings, supply the power to the camera, 
while holding down this switch with a 
pointed object.
q; m
 (microphone input) jack 
(minijack, monaural)
Connect a commercially available 
microphone. This jack supports plug-in-
power microphones (rated voltage: 2.4 
V DC).
You can connect the microphones of the 
following specifications to this camera.
Type: Electric condenser microphone 
Plug-in power system
Directivity: Nondirectional
Sensitivity: – 40 ± 3.5 dB
Frequency range: 50 – 15,000 Hz
qa 5
 (line output) jack (minijack, 
monaural)
Connect a commercially available 
speaker system with the built-in 
amplifier.
You can connect the speakers of the 
following specifications to this camera.
Type: Active speaker
Impedance: Input impedance 4.7 kohms 
or more
Plug: ø3.5 Mini-plug
qs
I/O (Input/Output) port
This port is provided with an RS-232C 
port, two sensor inputs and two alarm 
outputs.
The RS-232C port is used when you 
connect peripheral devices to the camera 
using the RS-232C interface, and control 
the devices from the computer or 
transmit/receive data from the devices 
via the network.
The sensor input is used as the alarm 
input.  The camera operation can be 
synchronized with E-mail or other 
applications.
IMAGE FLIP
m
5
1
2
+
DC 12V
AC 24V
121110 9 8 7 6 5 4 3 2 1
6
7
8
0
9
qa
qs
Rear