* ) Status  LED  indicator  (STATUS)  and  alarm  code  LED  indicator  (ALM  CODE)  start  flashing
simultaneously.
Protection
Error  counter
over  flow
*  EEPROM
parameter
error
*  EEPROM
check  code
error
Overttravel
inhibit
*  Other  error
Alarm
CodeNo.
2 9
3 6
3 7
3 8
9 9
*
C o u n t e r m e a s u r e s
Check  that  the  motor  operates  per  the
position  command  pulse.  See  the  torque
monitor  to  check  that  the  output  torque
does  not  get  saturated.  Readjust  the  gains.
Maximize  the  value  of  Pr5E  (torque  limit  set-
up).  Correct  the  encoder  wiring.
Set  all  the  parameters  again.  If  this  error
occurs  frequently,  the  amplifier  may  have
been  broken.  Replace  the  amplifier  with  a
new  one.  Return  the  old  amplifier  to  the
sales  agent  for  repair.
T h e   a m p l i f i e r   m a y   h a v e   b e e n   b r o k e n .
Replace  the  amplifier  with  a  new  one.  Return
the old amplifier to the sales agent for repair.
C h e c k   t h e   s w i t c h e s ,   w i r e s   a n d   p o w e r
supply  that  constitute  the  circuits.  Check
that  the  control  power  (12  to  24VDC)  can
be  established  without  delay.  Check  the
v a l u e   o f   P r 0 4 .   C o r r e c t   t h e   w i r i n g ,   i f
necessary.
Turn  off  the  power  and  turn  it  on  again.  If
the  error  cannot  be  eliminated,  the  motor
a n d / o r   a m p l i f i e r   m a y   b e   b r o k e n .
Discontinue  use  of  the  motor,  and  replace
the  motor  and  the  amplifier.  Return  the  old
equipment  to  the  sales  agent  for  repair.
C a u s e
The  value  of  the  position  error  counter  is
o v e r   2
2 7
  ( 1 3 4 2 1 7 7 2 8 ) .
The  data  contained  in  the  parameter  stor-
age  area  of  the  EEPROM  is  broken,
The  check  code  of  the  EEPROM  is  bro-
ken,
Both  the  CW  and  CCW  over-travel  limits
are  not  active.
The  control  circuit  operates  incorrectly
due  to  large  noises  or  any  other  reasons.
The  amplifier's  self-diagnosing  function  is
activated,  because  an  error  happens  in
the  amplifier.
Status LED
       red
       red
       orange
       orange
Alarm code LED
       red
       orange
       red
       orange