User Notes
1. Safety Approval
Toshiba Information System (U.K.) Ltd declare that the Strata CIX product ranges
comply with the EEC's LVD directive, (Directive No. 73/23/EEC). The product has
been assessed and found to comply with EN60950-1:2001.
comply with the EEC's LVD directive, (Directive No. 73/23/EEC). The product has
been assessed and found to comply with EN60950-1:2001.
The notes listed below form part of the products compliance with the aforementioned
European Nor
European Nor
IMPORTANT SAFETY NOTES:
1.1. All systems must have an earth connection and it must be hardwired to a main
earth distribution point. The main cabinet must be earthed.
earth distribution point. The main cabinet must be earthed.
1. 2. The table below identifies and classifies the ports available on the system:
Type of Circuit
(EN60950
Classification)
(EN60950
Classification)
Port Location
Port Description
SELV
Power Supply
BPSU672F/
APSU112F/
CHSUB192F
For connection of external 24 volt batteries.
SELV
Processor Boards
ACTU1F, ACTU2C,
BECU1F, BBCU1F,
BCTU2F, LCTU2C,
LCTU2R
For connection of external Music-On-Hold source and
Ethernet LAN connection.
Ethernet LAN connection.
SELV
AETS1A
Ethernet I/F for CIX100 only
SELV
BDKU/BDKS/BWDKU
For connection of Toshiba proprietary terminals.
SELV
BSIS1A
For connection of Voice Mail and Call Logging
Equipment. RS232 ports.
Equipment. RS232 ports.
TNV3
RSTU1F/RSTU3F/
BSTU1F/BSLU1F/
BSLS1F/ASTU1F/
LSLU
For connection of Approved 2 wire devices.