Honda cbr954rr Instruction De Maintenance

Page de 9
SYSTEM 
ITEM 
Battery 
Capacity 
Current  leakage 
Voltage 
Fully charged 
Needs charging 
Charging current 
Normal 
Quick 
Alternator 
Capacity 
Charging coil resistance 
The  battery will self-discharge when the motorcycle is not in use.  For this reason, charge the battery every 
weeks t o  pre- 
vent sulfation f r o m  occurring. 
When checking the charging system,  always follow 
the steps i n  t h e  troubleshooting f l o w  chart (page 16-3). 
For  battery charging,  do  not exceed  the  charging current and t i m e  specified o n  the  battery.  Use  o f  excessive  current 
or 
charging time m a y  damage t h e  battery. 
SPECIFICATIONS 
12V 
8.6  A h  
0.2 
max. 
13.0 
- 13.2 V 
Below 12.3 V 
0.9 
4.0 
0.421 
rpm 
0.1 
- 1.0 
BATTERY TESTING 
Refer t o  the instruction o f  the Operation Manual for the recommended battery tester.  The recommended battery tester  puts a 
"load" on the battery 
so 
that the actual battery condition of the load can be measured. 
Recommended battery tester 
BM-210-AH or BM-210 
only) 
SPECIFICATIONS 