kymco mo zx50 Instruction De Maintenance

Page de 9
16
. INSTRUMENT/SWITCHES/LIGHTS
16-2
ZX / SCOUT 50
FUEL UNIT
REMOVAL
Remove the frame body cover. (12-5)
Disconnect the fuel unit wire connectors.
Turn the fuel unit retainer counterclockwise
to remove it.
Remove the fuel unit.
INSPECTION
Remove the fuel unit.
Measure the resistance between the fuel
unit wire terminals with the float at upper
and lower positions.
Wire Terminals
Upper
Lower
G_
Y/W
33Ω
686Ω
G_
L/W
566Ω
53Ω
Y/W_
L/W
600Ω
600Ω
FUEL GAUGE INSPECTION
Connect the fuel unit wire connectors and
turn the ignition switch “ON”.
Check the fuel gauge needle for correct
indication by moving the fuel unit float up
and down.
Float Position
Needle Position
Upper
“F” (Full)
Lower
“E” (Empty)
Y/W
AC 110V
Fuel Unit Wire
Fuel Unit
G
L/W