kymco mo d200 Instruction De Maintenance

Page de 6
17
. IGNITION SYSTEM
17-5
DINK 200
RESISTANCE INSPECTION
Measure the resistance between the terminals.
Replace the CDI unit if the readings are not
within the specifications in the table below.
Use the 
x
 KΩ range for the Sanwa Tester.
Use the
 x
 100Ω range for the Kowa Tester.
                                                     Unit: KΩ
(+)Probe
(-)Probe
(Black/Blue) (Black/Yellow) (Green/White)
(Blue/Yellow)
(Green)
(Black/Blue)
150~280
20~30
20~30
(Black/Yellow)
75~100
50~70
50~70
(Green/White)
7~10
50~70
(Blue/Yellow)
7~10
50~70
(Green)
Different data from different supplier.
 (Green/White)
(Green)
(Black/Yellow)
 (Black/Blue)
(Blue/Yellow)
• Due to the semiconductor in circuit, it
is necessary to use a specified tester
for accurate testing.  Use of an
improper tester in an improper range
may give false readings.
• Use a Sanwa Electric Tester (07308-
0020000) or Kowa Electric Tester
(TH-5H).
• In this table, “Needle swings then
returns” indicates that there is a
charging current applied to a condenser.
The needle will then remain at “∞ ”
unless the condenser is discharged.