kymco mo super 950 Instruction De Maintenance

Page de 15
11
. COOLING SYSTEM
11-2
SUPER 9  50
SPECIFICATIONS
  Begins to open
80±2℃
 Thermostat temperature
  Full-open
90℃
  Valve lift
3.5_
4.5mm
 Coolant capacity
Total system 1165cc  Radiator: 825cc
 Reserve tank: 340cc
COOLANT GRAVITY
Temp.  ℃
Coolant
concentration
0
5
10
15
20
25
30
35
40
45
50
5%
1.009 1.009 1.008 1.008 1.007 1.006 1.005 1.003 1.001 0.009 0.997
10%
1.018 1.107 1.017 1.016 1.015 1.014 0.013 1.011 1.009 1.007 1.005
15%
1.028 1.027 1.026 1.025 1.024 1.022 1.020 1.018 1.016 1.014 1.012
20%
1.036 1.035 1.034 1.033 1.031 1.029 1.027 1.025 1.023 1.021 1.019
25%
1.045 1.044 1.043 1.042 1.040 1.038 1.036 1.034 1.031 1.028 1.025
30%
1.053 1.051 1.051 1.049 1.047 1.045 1.043 1.041 1.038 1.035 1.032
35%
1.063 1.062 1.060 1.058 1.056 1.054 1.052 1.049 1.046 1.043 1.040
40%
1.072 1.070 1.068 1.066 1.064 1.062 1.059 1.056 1.053 1.050 1.047
45%
1.080 1.078 1.076 1.074 1.072 1.069 1.056 1.063 1.062 1.057 1.054
50%
1.086 1.084 1.082 1.080 1.077 1.074 1.071 1.068 1.065 1.062 1.059
55%
1.095 1.093 1.091 1.088 1.085 1.082 1.079 1.076 1.073 1.070 1.067
60%
1.100 1.098 1.095 1.092 1.089 1.086 1.083 1.080 1.077 1.074 1.071
COOLANT MIXTURE (WITH ANTI-RUST AND ANTI-FREEZING EFFECTS)
Freezing Point
Mixing Rate KYMCO SIGMA Coolant Concentrate Distilled Water
     -9℃
20%
     -15℃
30%
360cc
825cc
     -25℃
40%
     -37℃
50%
     -44.5℃
55%
Cautions for Using Coolant:
• Use coolant of specified mixing rate. (The
mixing rate of 360cc KYMCO SIGMA
coolant concentrate + 825cc distilled
water is 30%.)
• Do not mix coolant concentrate of
different brands.
• Do not drink the coolant which is
poisonous.
• The freezing point of coolant mixture shall
be 5℃ lower than the freezing point of
the riding area.