kymco mo x500 Instruction De Maintenance

Page de 33
1
. GENERAL INFORMATION
1-30
XCITING 500
POOR CHARGING (BATTERY OVER DISCHARGING OR OVERCHARGING)
Undercharging
cFaulty AC generator
dFaulty regulator/rectifier
eFaulty battery
cShorted AC generator coil
dOpen circuit between AC
generator 3 yellow wires
cFaulty regulator/rectifier
dFaulty AC generator
eLoose regulator/rectifier
coupler
fLimit voltage too high
Overcharging
cFaulty battery
dFaulty regulator/rectifier
eBroken or poorly connected
regulator/rectifier black wire
cLimit voltage too high
Start engine and test
limit voltage of battery
terminals
Measure battery limit
voltage with an electric
tester
Test output voltage of
regulator/rectifier
coupler red wire
Inspection/Adjustment
Inspection/Adjustment
Symptom
Symptom
Probable Cause
Probable Cause
Normal voltage
Normal
Normal
Voltage does not
increase
Abnormal
Resistance too low
Normal voltage
No voltage
Measure resistance
between AC generator
coil terminals
Check resistance
between regulator/
rectifier terminals
Normal
Abnormal