Using LANVIEW
Matrix DFE-Gold Series Modules Hardware Installation Guide 4-5
Table 4-1 LANVIEW LEDs
LED
Color
State
Recommended Action
MGMT
None
Off. This module is NOT the 
Management Module.
None.
Green 
Solid. This module is the 
designated Management 
Module.
None.
Amber 
Flashing. This is a 
temporary indication that the 
module is saving data.
None.
CPU
None
Power off.
Ensure chassis has adequate power.
Amber
Blinking. Module in process 
of booting. 
None.
Solid. Testing.
If the LED remains amber for several 
minutes, contact Enterasys Networks 
for technical support.
Green
Blinking. Image starts 
running.
None.
Solid. Functional.
None.
Red
Solid. Processor in reset.
None.
Green 
and 
Amber
Blinking. Indicates that the 
module is in the process of 
shutting down.
None. This state is activated when the 
OFFLINE/RESET switch is pressed for 
less than 1 second to start the process 
of an orderly shutdown.
While in this state, do not remove any 
DFE-Gold module.
Amber 
and Off
Alternately (67% on, 33% 
off)
. Indicates that a 
shutdown process has 
completed. This indication 
will remain for 60 seconds 
before automatically 
restarting.
While in this state, you have 60 seconds 
to safely remove the DFE-Gold module 