Page de 65
-2-
SAFETY PRECAUTIONS
CAUTION
:  DO  NOT  ATTEMPT  TO  MODIFY  THIS  PRODUCT  IN  ANY  WAY.
NEVER  PERFORM  CUSTOMIZED  INSTALLATIONS  WITHOUT  MANUFAC-
TURER’S APPROVAL. UNAUTHORIZED MODIFICATIONS WILL NOT ONLY VOID
THE WARRANTY, BUT MAY LEAD TO YOUR BEING LIABLE FOR ANT RESULT-
ING PROPERTY DAMAGE OR USER INJURY.
SERVICE  WORK  SHOULD  BE  PERFORMED  ONLY  AFTER  YOU  ARE  THOR-
OUGHLY  FAMILIAR  WITH  ALL  OF  THE  FOLLOWING  SAFETY  CHECKS  AND
SERVICING  GUIDELINES.  TO  DO  OTHERWISE,  INCREASES  THE  RISK  OF
POTENTIAL HAZARDS AND INJURY TO THE USER.
WHILE  SERVICING,  USE  AN  ISOLATION  TRANSFORMER  FOR  PROTECTION
FROM A.C. LINE SHOCK.
SAFETY CHECKS
AFTER THE ORIGINAL SERVICE PROBLEM HAS BEEN CORRECTED, A CHECK
SHOULD BE MADE OF THE FOLLOWING:
SUBJECT:FIRE & SHOCK HAZARD
1. BE  SURE  THAT  ALL  COMPONENTS  ARE  POSITIONED  IN  SUCH  A  WAY  AS
TO  AVOID  POSSIBILITY  OF  ADJACENT  COMPONENT  SHORTS.  THIS  IS
ESPECIALLY  IMPORTANT  ON  THOSE  MODULES  WHICH  ARE  TRANS-
PORTED TO AND FROM THE REPAIR SHOP.
2. NEVER RELEASE A REPAIR UNLESS ALL PROTECTIVE DEVICES SUCH AS
INSULATORS,  BARRIERS,  COVERS,  SHIELDS,  STRAIN  RELIEFS,  POWER
SUPPLY CORDS, AND OTHER HARDWARE HAVE BEEN REINSTALLED PER
ORIGINAL  DESIGN.  BE  SURE,  THAT  THE  SAFETY  PURPOSE  OF  THE
POLARIZED LINE PLUG HAS NOT BEEN DEFEATED.
3. SOLDERING  MUST  BE  INSPECTED  TO  DISCOVER  POSSIBLE  COLD  SOL-
DER  JOINTS,  SOLDER  SPLASHES  OF  SHARP  SOLDER  POINTS.  BE  CER-
TAIN TO REMOVE ALL LOOSE FOREIGN PARTICLES.
4. CHECK  FOR  PHYSICAL  EVIDENCE  OF  DAMAGE  OR  DETERIORATION  TO
PARTS  AND  COMPONENTS,  FOR  FRAYED  LEADS,  DAMAGED  INSULATION
(INCLUDING  A.C.  CORD),  AND  REPLACE  IF  NECESSARY.  FOLLOW  ORIGI-
NAL LAYOUT, LEAD LENGTH AND DRESS.
5. NO  LEAD  OR  COMPONENT  SHOULD  TOUCH  A  RECEIVING  TUBE  OR  A
RESISTOR  RATED  AT  1  WATT  OR  MORE.  LEAD  TENSION  AROUND  PRO-
TRUDING METAL SURFACES MUST BE AVOIDED.
6. ALL  CRITICAL  COMPONENTS  SUCH  AS  FUSES,  FLAMEPROOF  RESISTOR,
CAPACITORS,  ETC.  MUST  BE  REPLACED  WITH  EXACT  FACTORY  TYPES.
DO  NOT  USE  REPLACEMENT  COMPONENTS  OTHER  THAN  THOSE  SPECI-
FIED OR MAKE UNRECOMMENDED CIRCUIT MODIFICATIONS.
7. AFTER  RE-ASSEMBLY  OF  THE  STE  ALWAYS  PERFORM  AN  A.C.  LEAKAGE
TEST  ON  ALL  EXPOSED  METALLIC  PARTS  OF  THE  CABINET.  (THE  CHAN-
NEL SELECTOR KNOB, ANTENNA TERMINALS, HANDLE AND SCREWS) TO
BE SURE THE SET IS SAFE TO OPERATE WITHOUT DANGER OF ELECTRI-
CAL SHOCK. DO NOT USE A LINE ISOLATION TRANSFORMER DURING THIS
TEST USE AN A.C. VOLTMETER, HAVING 5000 OHMS PER VOLT OR MORE
SENSITIVITY,  IN  THE  FOLLOWING  MANNER  :  CONNECT  A  1500  OHM  10
WATT  RESISTOR,  PARALLELED  BY  A    .15  MFD.  150V  A.C.  TYPE  CAPACI-
TOR  BETWEEN  A  KNOWN  GOOD  EARTH  GROUND  (WATER  POPE,  CON-
DUIT,  ETC.)  AND  THE  EXPOSED  METALLIC  PARTS,  ONE  AT  A  TIME.
MEASURE  THE  A.C.  VOLTAGE  ACROSS  THE  COMBINATION  OF  1500  OHM
RESISTOR  AND  .15  MFD  CAPACITOR.  REVERSE  THE  A.C.  PLUG  AND
REPEAT  A.C.  VOLTAGE  MEASUREMENTS  FOR  EACH  EXPOSED  METALLIC
PART.  VOLTAGE  MEASURED  MUST  NOT  EXCEED  .75  VOLTS  R.M.S  THIS
CORRESPONDS TO 0.5 MILLIAMP A.C. NAY VALUE EXCEEDING THIS LIMIT
CONSTITUTES A POTENTIAL SHOCK HAZARD AND MUST BE CORRECTED
IMMEDIATELY.
SUBJECT : X-RADIATION
1. BE  SURE  PROCEDURES  AND  INSTRUCTIONS  TO  ALL  SERVICE  PERSON-
NEL  COVER  THE  SUBJECT  OF  X-RADIATION.  THE  ONLY  POTENTIAL
SOURCE OF X-RAYS IN CURRENT T.V. RECEIVERS IS THE PICTURE TUBE.
HOWEVER,  THIS  TUBE  DOES  NOT  EMIT  X-RAYS  WHEN  THE  HIGH  VOLT-
AGE IS AT THE FACTORY SPECIFIED LEVEL. THE PROPER VALUE IS GIVEN
IN THE APPLICABLE SCHEMATIC. OPERATION AT HIGHER VOLT-AGES MAY
CAUSE  A  FAILURE  OF  THE  PICTURE  TUBE  OR  HIGH  VOLTAGE  SUPPLY
AND  UNDER  CERTAIN  CIRCUMSTANCES,  AMY  PRODUCE  RADIA-TION  IN
EXCESS OF DESIRABLE LEVELS.
2. ONLY  FACTORY  SPECIFIED  C.R.T  ANODE  CONNECTORS  MUST  BE
USED.DEGAUSSING  SHIELDS  ALSO  SERVE  AS  X-RAY  SHIELD  IN  COLOR
SETS. ALWAYS RE-INSTALL THEM.
3. IT IS ESSENTIAL THAT SERVICE PERSONNEL HAVE AVAILABLE AN ACCU-
RATE  AND  RELIABLE  HIGH  VOLTAGE  METER.  THE  CALIBRATION  OF  THE
METER  SHOULD  BE  CHECKED  PERIODICALLY  AGAINST  A  REFERENCE
STANDARD. SUCH AS THE ONE AVAILABLE AT YOUR DISTRIBUTOR.
4. WHEN  THE  HIGH  VOLTAGE  CIRCUITRY  IS  OPERATING  PROPERLY  THERE
IS NO POSSIBILITY OF AN X-RADIATION PROBLEM. EVERY TIME A COLOR
CHASSIS IS SERVICED, THE BRIGHTNESS SHOULD BE RUN UP AND DOWN
WHILE  MONITORING  THE  HIGH  VOLTAGE  WITH  A  METER  TO  BE  CERTAIN
THAT THE HIGH VOLTAGE DOES NOT EXCEED THE SPECIFIED VALUE AND
THAT IT IS REGULATING CORRECTLY. WE SUGGEST THAT YOU AND YOUR
SERVICE ORGANIZATION REVIEW TEST PROCEDURES SO THAT VOLTAGE
REGULATION  IS  ALWAYS  CHECKED  AS  A  STANDARD  SERVICING
PROCEDURE, AND THAT THE HIGH VOLTAGE READING BE RECORDED ON
EACH CUSTOMER S INVOICE.
5. WHEN  TROUBLESHOOTING  AND  MAKING  TEST  MEASUREMENTS  IN  A
PRODUCT WITH A PROBLEM OF EXCESSIVE HIGH VOLTAGE, AVOID BEING
UNNECESSARILY CLOSE TO THE PICTURE TUBE AND THE HIGH VOLTAGE
SUPPLY. DO NOT OPERATE THE PRODUCT LONGER THAN IS NECESSARY
TO LOCATE THE CAUSE OF EXCESSIVE VOLTAGE.
6. REFER  TO  HV,  B+  AND  SHUTDOWN  ADJUSTMENT  PROCEDURES
DESCRIBED  IN  THE  APPROPRIATE  SCHEMATIC  AND  DIAGRAMS  (WHERE
USED).
SUBJECT : IMPLOSION
1. ALL  DIRECT  VIEWED  PICTURE  TUBES  ARE  EQUIPPED  WITH  AN  INTEGRA
IMPLOSION  PROTECTION  SYSTEM.  BUT  CARE  SHOULD  BE  TAKEN  TO
AVOID  DAMAGE  DURING  INSTALLATION.  AVOID  SCRATCHING  THE  TUBE.
OF SCRATCHED REPLACE IT.
2. USE ONLY RECOMMENDED FACTORY REPLACEMENT TUBES.
SUBJECT : TIPS ON PROPER INSTALLATION
1. NEVER INSTALL ANY PRODUCT IN A CLOSED-IN RECESS, CUBBYHOLE OR
CLOSELY FITTING SHELF SPACE, OVER OR CLOSE TO HEAT DUCT, OR IN
THE PATH OF HEATED AIR FLOW.
2. AVOID  CONDITIONS  OF  HIGH  HUMIDITY  SUCH  AS:  OUTDOOR  PATIO
INSTALLATIONS  WHERE  DEW  IS  A  FACTOR,  NEAR  STEAM  RADIATORS
WHERE STEAM LEAKAGE IS A FACTOR, ETC.
3. AVOID PLACEMENT WHERE DRAPERIES MAY OBSTRUCT REAR VENTING.
THE  CUSTOMER  SHOULD  ALSO  AVOID  THE  USE  OF  DECORATIVE
SCARVES  OR  OTHER  COVERINGS  WHICH  MIGHT  OBSTRUCT  VENTILA-
TION.
4. WALL  AND  SHELF  MOUNTED  INSTALLATIONS  USING  A  COMMERCIAL
MOUNTING  KIT,  MUST  FOLLOW  THE  FACTORY  APPROVED  MOUNTING
INSTRUCTIONS. A PRODUCT MOUNTED TO A SHELF OR PLATFORM MUST
RETAIN  ITS  ORIGINAL  FEET  (OR  THE  EQUIVALENT  THICKNESS  IN  SPAC-
ERS)TO PROVIDE ADEQUATE AIR FLOW ACROSS THE BOTTOM, BOLTS OR
SCREWS  USED  FOR  FASTENERS  MUST  NOT  TOUCH  ANY  PARTS  OR
WIRING. PERFORM LEAKAGE TEST ON CUSTOMIZED INSTALLATIONS.
5. CAUTION  CUSTOMERS  AGAINST  THE  MOUNTING  OF  A  PRODUCT  ON
SLOPING  SHELF  OR  A  TILTED  POSITION,  UNLESS  THE  PRODUCT  IS
PROPERLY SECURED.
6. A PRODUCT ON A ROLL-ABOUT CART SHOULD BE STABLE ON ITS MOUNT-
ING TO THE CART. CAUTION THE CUSTOMER ON THE HAZARDS OF TRY-
ING  TO  ROLL  A  CART  WITH  SMALL  CASTERS  ACROSS  THRESHOLDS  OR
DEEP PILE CARPETS.
7. CAUTION  CUSTOMERS  AGAINST  THE  USE  OF  A  CART  OR  STAND  WHICH
HAS  NOT  BEEN  LISTED  BY  UNDERWRITERS  LABORATORIES.  INC.  FOR
USE  WITH  THEIR  SPECIFIC  MODEL  OF  TELEVISION  RECEIVER  OR
GENERICALLY APPROVED FOR USE WITH T.V.S OF THE SAME OR LARGER
SCREEN SIZE.
8. CAUTION  CUSTOMERS  AGAINST  THE  USE  OF  EXTENSION  CORDS,
EXPLAIN  THAT  A  FOREST  OF  EXTENSIONS  SPROUTING  FROM  A  SINGLE
OUTLET  CAN  LEAD  TO  DISASTROUS  CONSEQUENCES  TO  HOME  AND
FAMILY.
THE  LIGHTNING  FLASH  WITH  ARROWHEAD  SYMBOL,
WITHIN  AN  EQUILATERAL  TRIANGLE,  IS  INTENDED  TO
ALERT THE SERVICE PERSONNEL TO THE PRES-ENCE
OF UNINSULATED  DANGEROUS VOLTAGE  
THAT  MAY  BE  OF  SUFFICIENT  MAGNITUDE  TO  CON-
STITUTE A RISK OF ELECTRIC SHOCK.
THE  EXCLAMATION  POINT  WITHIN  AN  EQUILATERAL
TRIANGLE  IS  INTENDED  TO  ALERT  THE  SERVICE
PERSONNEL  TO  THE  PRESENCE  OF  IMPORTANT
SAFETY INFORMATION ON SERVICE LITERATURE.
SUBJECT : GRAPHIC SYMBOLS
10WATT
GOOD EARTH GROUND
SUCH AS THE WATER
PIPE, CONDUIT, ETC.
1500       OHM
A.C. VOLTMETER
PLACE THIS PROBE
ON EACH EXPOSED
METAL PART
0.15 uF