15, 30, & 60 cfm Compact Dryers 
 
19 
 
trapped air from the system. Make sure the aftercooler has the proper supply water 
temperature. 
6.  Set the process set point on the temperature controller. 
7.  After the proper pre-drying time for the initial hopper fill has elapsed, fully open the 
drying hopper slide gate. 
Note: 
To allow proper residence time during continuous processing, 
maintain the material level in the hopper at the midpoint of the air trap 
assembly. 
Auto-Tuning the Dryer 
1.  For Auto-tuning, press the Level Key once. The 
AT
 screen will show 
with the setting 
OFF
.  
2.  Press UP arrow to change the setting to 
ON
3.  Press the Level Key again to the Temperature Screen. Your actual 
temperature will start to flash for about 10-20 minutes with the 
temperature fluctuating up and down during that period. After the 
flashing stops, it means auto-tuning has finished. 
Shutting Down the Dryer 
1. 
Turn off the conveying system supplying the drying hopper. 
2. 
When processing is complete, close the hopper slide gate and shut down any in-line 
companion equipment, such as the aftercooler. 
3. 
Turn the Dryer ON/OFF selector switch to OFF. 
4. 
Turn the system ON/OFF switch to OFF
5. 
If needed, empty the drying hopper. 
6. 
For maintenance or a long term shutdown, open (de-energize) the electrical 
disconnects at the dryer and at the power drop.