15, 30, & 60 cfm Compact Dryers 
 
34 
 
 
Replacing the Process/Regeneration Heater 
The dehumidifying dryers utilize a single-phase Calrod-type heater element.  This heater 
element is mounted in the center compartment in the desiccant beds. Although the 
replacement procedure is the same for each heater, the wattage varies by model, voltage, 
temperature range, etc. 
WARNING! 
Hazardous electrical current present. 
Disconnect and lock out power before you replace heater elements! 
 
Figure 12:  Process/Regeneration Heater Location and Disassembly 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Procedures 
1.  Disconnect electrical power to the dryer. 
2.  Using a 1/8” Allen wrench, remove the 10-24 button head screws holding the top, 
back and side panels to the dryer frame. 
3.  Disconnect the plug for the valve motor, valve switch, and blower (15 only). 
4.  Remove the four (4) nuts at each corner of the top casting. 
Valve & Air 
Manifold Casting
Desiccant 
Assembly Rod
Regeneration 
Heater
Wire Conduit 
Assembly
Lower Air Manifold Casting
Gasket
Hollow 
Desiccant 
Tank