15, 30, & 60 cfm Compact Dryers 
 
38 
 
 
Alarm Message 
Cause 
Corrective Action 
Dryer Status 
The process 
temperature has 
exceeded the alarm 
set point. 
The process heater 
contactor has failed in the 
closed position. Check 
heater contactor, replace if 
necessary. 
Check the Process Heater 
box high temperature snap 
switch, replace if necessary 
The high temperature 
snap switch of the 
process heater box 
has tripped. 
The Regeneration heater 
contactor has failed in the 
closed position. Check 
heater contactor, replace if 
necessary. 
The high temperature 
snap switch on of the 
regeneration heater 
boxes has tripped 
 
 
Check the high temperature 
snap switches on the 
regeneration heater 
mounting plates, replace if 
necessary. 
HIGH TEMP 
 
Process blower 
pressure switch is not 
detecting pressure. 
Check the blower fusing, or 
the blower motor.  Make 
sure the wire and hose 
connections are correct. 
- Dryer Shuts down: 
- Process blower OFF. 
- Process heaters OFF. 
- Regen heaters OFF. 
- Alarm light is ON 
- Alarm horn is ON. 
Make sure the process air 
filter is clean. Clean or 
replace if necessary. 
Check the rotation of the 
blower. 
Check the pressure switch 
hose connection. Replace 
hoses or the pressure 
switch. 
Check the over load rating 
against the wiring diagram. 
Adjust accordingly. 
Check the wiring of the 
blower. Make sure it is wired 
for the proper voltage. 
Check the process blower 
fuses for any fault. Replace 
if necessary. 
Check the blower motor 
starter. Replace if 
necessary. 
Check the blower motor. 
Replace if necessary. 
PROC BLWR 
 
The process blower 
pressure switch did not 
detect enough 
pressure. 
Process blower 
overload has tripped. 
Process blower motor 
has failed. 
Check the incoming voltage 
against the name plate of 
the dryer.