Epson stylus 870 Manuel D’Utilisation

Page de 74
 
 
EPSON Imaging Technology Center 
 
Page: 41 
Revision: 1 
 
10/6/00 
6.20 Set relative vertical print position “ESC (v nL nH m1 m2 m3 m4”  
Format:  
ASCII  
ESC 
v  nL nH m1 m2 m3 m4 
  Hex 
 1B 
28 
76 
nL 
nH 
m1 
m2 
m3 
m4 
Decimal 
27  40  118 nL  nH m1 m2 m3 m4 
Range of Values for Parameters: 
 nL=04H, 
nH=00H 
0 <= (m4*1000000H +m3*10000H + m2*10H + m1))×(relative vertical  position set 
unit)inch <= 1FFFFFFFH/1440 inch 
Function: 
1) 
The printing position in the Y direction is set to a position spaced in the positive 
direction from the present Y printing position in the Y direction by 
(m4*256*256*256 + m3*256*256 + m2*256 + m1) x (relative vertical position 
set unit) inches. 
  Setting 
in 
theystem. 
2) 
If the position set by this command is higher than the top margin position on the 
current page, this command is ignored. 
3) 
If the printing position in the Y direction has been set by this command to a non-
printable region, then the position management coordinate system is set to the 
next page, and the printing position in the Y direction is reset to the origin upon 
the Y axis of the new position management coordinate system. 
 Initial State:  - 
Related Commands: 
 
Commands related in the direction of applying an effect (Setting) 
  None 
 
Commands related in the direction of receiving an effect (Setting) 
  None 
 
Commands related in the direction of applying an effect (Operation) 
  None 
 
Commands related in the direction of receiving an effect (Operation) 
 
 
The relative vertical position setting units are set by the ESC (U command. 
 
 
The non-printable region is set by the ESC (c commands. 
The relative vertical position setting units, the non-printable region, and the 
printing position in the Y direction are reset to their initial states by the ESC @ 
and ESC (G commands.