temco-tool dv1000n-p Manuel D’Utilisation

Page de 40
11
Temco DV1000/1200/1400 Series
76657
NOTE:  Use only venting systems and components 
as certified with the appliance. Use of uncertified vent 
systems or components will void the warranty and may 
compromise the operation of the fireplace, its systems, 
and components as certified with the appliance.
2" (51mm)
1" (25mm)
1" 
(25mm)
T181
vent clearances
12/3/03  djt
Top of Vent
Combustibles 
NOT Allowed in 
Shaded Area
4” Dia. Flue
7” Dia. Intake 
Vent
T181
Fig. 11  Vent clearances.
0
5'
46"
(1168mm)
33¹⁄₂"
(851mm)
10'
15'
25'
30'
32'
0
3'
5'
10'
15'
T180
DV vent graph
12/3/03  djt
*
A vent guard should be 
used whenever the termina-
tion is lower than the speci-
fied minimum or as per local 
codes
* Min. Refer to Chart on Page 6
T180
Fig. 12  Venting graph.
Fig. 10  Termination clearances.
Outside Corner
Inside Corner
Termination Clearances
Termination clearances for buildings with combustible and noncombustible exteriors. 
G =
Combustible 
  6" (152 mm)
Noncombustible 
  2" (51 mm)
F =
Combustible 
  6" (152 mm)
 
Noncombustible 
  2" (51 mm)
G
Balcony - 
with no side wall
M = 
Combustible &
Noncombustible
  12" (305 mm)
M
Balcony - 
with perpendicular side wall
M = 24" (610 mm)
P = 20” (508 mm)
M
F
Alcove Applications*
C
D
C
E
V
V
Combustible &
Noncombustible
V
V
V
E
 = Min. 6” (152 mm) for 
non-vinyl sidewalls
Min. 12” (305 mm) for
vinyl sidewalls
O
 = 8’ (2.4 m) Min.
O
P
584-15
 
No. 
  of Caps 
 
D
Min.
 
  C
Max.
 
3’ (914 mm)  2 x D
Actual
 
6’ (1.8 m) 
1 x D
Actual
 
9’ (2.7 m) 
2/3 x D
Actual
 
12’ (3.7 m) 
1/2 x D
Actual
D
Min.
 = # of Termination caps x 3
C
Max.
 = (2 / # termination caps) x D
Actual
*NOTE: Termination in an alcove space (spaces open only on one side and with an overhang) is permitted with the dimensions 
specified for vinyl or non-vinyl siding and soffits. 1. There must be a 3’ (914 mm) minimum between termination caps. 2. All 
mechanical air intakes within 10’ (1 m) of a termination cap must be a minimum of 3’ (914 mm) below the termination cap. 3. All 
gravity air intakes within 3’ (914 mm) of a termination cap must be a minimum of 1’ (305 mm) below the termination cap.