temco-tool 33rdvdsn Manuel D’Utilisation

Page de 44
27
RDVDSN Series Direct Vent Gas Fireplace
20007894
Fuel Conversion Instructions
WARNING: This conversion kit must ONLY be ap-
plied as part of a conversion kit supplied by the ap-
pliance manufacturer for the specific appliance and 
type of gas being converted.
The conversion shall be carried out in accordance 
with the requirements of the provincial authori-
ties having jurisdiction and in accordance with the 
requirements of the CSA B149.2 Installation Code 
(Canada) and with the requirements of the National 
Fuel Gas Code Z223.1/NFPA 54 (United States).
WARNING: This conversion kit shall be installed 
by a qualified service agency in accordance with 
the manufacturer’s instructions and all applicable 
codes and requirements of the authority having 
jurisdiction. If the information in this instruction is 
not followed exactly, a fire, explosion or production 
of carbon monoxide may result causing property 
damage, personal injury or loss of life. The qualified 
service agency is responsible for the proper instal-
lation of this kit. The installation is not proper and 
complete until the operation of the converted appli-
ance is checked as specified in the manufacturer’s 
instructions supplied with the kit.
Installer Notice: Using an ink pen, fill out the re-
quired information on the conversion label. Remove 
the backing from label and stick label in a visible 
position on bottom of fireplace close to gas valve.
Installer Notice: These instructions must be left with 
the appliance.
Instructions for converting your fireplace from Natural 
gas to Propane/LP gas.
All fireplaces are shipped from the factory equipped to 
operate on Natural gas. To convert the fireplace to oper-
ate on Propane/LP gas, follow the instructions below. 
Please see the appropriate parts list for your model for 
parts included with the fireplace.
Check the items in the kit with the parts list. Notify the 
supplier of any items that are missing before installing 
the conversion kit. 
1.  Turn off gas supply.
2.  Turn off the electrical supply to the appliance if so 
equipped.
Fig. 47  Bend tabs down, loosen split nut assembly and slide 
burner tube to the left.
T257
fuel conversion
6/04
Burner Tabs
Split Nut Assembly
T257
Attention: All fireplaces are shipped from the fac-
tory equipped for natural gas. Units must be con-
verted for use with propane (LP) gas.
Replace Burner Orifice
All Models:
Remove the two (2) screws holding the pilot to the 
burner bracket.
FC100
fuel conversoin
burner tube
7/21/99   djt
Retaining Bracket
Burner Tube
FC100
Fig. 45  Bend retaining bracket away from tube.
FC105
manifold to 
air shutter
4/30/02   djt
Burner Tube
Air Shutter
Split Nut 
Assembly
FC105
Fig. 46  Loosen split nut assembly from air shutter and remove 
burner tube.
36/39RDVDSN:
1.  Remove lava rock to expose screws and remove 
grate assembly.
2.  Use screwdriver and bend burner tabs outward. (Fig. 
47)
3.  Loosen the split nut assembly to remove from burner/
air shutter. Slide burner tube to the left and off burner 
orifice. (Fig. 47)
33RDVDSN:
1.  Remove the two (2) Phillips head screws from the 
burner tube retaining bracket. (Fig. 45)
2.  With suitable tool, loosen the split nut assembly from 
the air shutter. (Fig. 46) Lift burner tube up and away.
All Models:
1.  Using a suitable tool replace natural orifice #47 with 
propane orifice #56 for model 33RDVDSP, or replace 
natural orifice #45 with propane orifice #55 for model 
36RDVDSP, or replace natural orifice #42 with pro-
pane orifice #54 for model 39RDVDSP furnished with 
conversion kit. Tighten orifice with suitable tool until 
gas tight. (Fig. 48)