Alliance Laundry Systems 1305 Manuel D’Utilisation

Page de 111
PowerFlex 40 and 400 Drive Control Logic
F232120
10
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Control Terminal Blocks Description and 
Control Logic
NOTE: Do not connect AC drive digital common, 
analog common, or common terminals to chassis 
ground. 
Input Mode Parameter
The control terminal functions are determined in part 
by the “Start Source” parameter #36. Changing this 
parameter affects the function of some terminals.
Speed Selection
Motor speeds on digitally-controlled AC drives are 
controlled by solid state or mechanical switch closure 
inputs to Digital In 1, Digital In 2, and Digital In 3 
terminals. Similarly, motor rotation direction is 
controlled by inputs to Start/Run FWD and Direction/
Run REV terminals. Refer to Figure 10.
An inactive control input terminal (H) will measure 
approximately 24v DC while an active control input 
terminal (L) will measure less than 1v DC. When a 
control input (i.e., Digital In 1, 2, 3, 4, Fwd, Rev, or 
Stop) is connected to a common terminal (terminal 4), 
the voltage on the control input terminal is reduced to 
near zero and the input is activated. 
Tables 8 – 14 designate the speed and rotation 
direction based on inputs to the control terminals. The 
AC drive’s input status parameters display of 1s and 0s 
at various machine actions can be viewed while 
monitoring parameter #13 and/or #14. When the 
control input terminal voltage is high (inactive) the 
status display will read “0” (logic 0). When the control 
input terminal voltage is low (active) the status will 
read “1” (logic 1).
Balance Output
The AC drive balance output signal is transmitted to 
the machine controller by the operation of an on-board 
normally open relay or transistor. Refer to Figure 10
The AC drive will analyze the wash load distribution 
during certain drain steps and communicate the 
severity of load imbalance to the machine controller. 
The machine controller then determines if the load is 
suitably distributed for the programmed spin speed. 
The severity of load imbalance is communicated 
digitally by the on-board relay or transistor using a 
series of pulses or continuous open or closed state.
Stop/Enable Input
The Stop Input function is machine dependent. The 
input is typically used to disable the drive either when 
the frame vibration safety limit switch has been 
tripped or when the loading door has been opened. 
Refer to the applicable machine electrical schematic 
for details on the connection of this input. When the 
Stop Input signal is interrupted, the control input 
signals must be removed and reapplied to restart the 
motor operation. 
WARNING
To reduce risk of electric shock, severe 
injury or death, allow machine power to 
remain off for three minutes minimum prior 
to working in and around AC drive. Proceed 
with caution.
W662
CAUTION
Never permanently jumper the AC drive 
balance output terminals or short the wires 
in these terminals together. This will 
override the balance detection routine and 
cause the wash cycle to abort, potentially 
causing machine damage or personal injury 
in the process.
W671