Dryer Exhaust Requirements . . .
Never install flexible duct in concealed spaces, such as a 
wall or ceiling.
Exhaust System Materials
Exhaust system materials are not supplied with the dryer 
unit.
Exhaust duct must be four inches (10.2 cm) in diameter 
having no obstructions. Rigid metal duct is 
recommended. Non-combustible semi-rigid flexible 
metal duct is acceptable. Do not use plastic pipe or 
flexible plastic pipe, because it contributes to poor drying 
performance and collects lint, which can lead to a fire 
hazard.
DO NOT use sheet metal screws on exhaust pipe joints or 
other fastening means which extend into the duct that 
could catch lint and reduce the efficiency of the exhaust 
system. Secure all joints with duct tape.
NOTE: Kits described above are optional exhaust 
system materials available at extra cost.
Make-Up Air Requirements
A dryer unit exhausts 214 cfm (measured at back of dryer 
unit) and sufficient make-up air must be supplied to 
replace air exhausted by each dryer unit.
An unobstructed opening of at least 40 square inches 
(260 cm
2
) of outdoor make-up air MUST be provided for 
each dryer unit. Protective louvers in the opening to the 
outdoors can reduce air movement approximately 35 to 
40 percent. Be sure the opening is large enough to 
compensate for any louvers.
If it is necessary to duct make-up air to the dryer unit, 
increase the area of the ductwork by 25 percent to 
compensate for any reduction in air movement. In 
addition, the make-up air duct should extend down to 
within approximately two feet from the floor, directly 
behind the dryer unit.
A clothes dryer produces combustible lint. To 
reduce the risk of fire and combustion gas 
accumulation the dryer MUST be exhausted to 
the outdoors.
W116
This gas appliance contains or produces a 
chemical or chemicals which can cause death 
or serious illness and which are known to the 
State of California to cause cancer, birth 
defects, or other reproductive harm. To 
reduce the risk from substances in the fuel or 
from fuel combustion, make sure this 
appliance is installed, operated, and 
maintained according to the instructions in 
this manual.
W115
To reduce the risk of fire and the 
accumulation of combustion gases, DO NOT 
exhaust dryer air into a window well, gas vent, 
chimney or enclosed, unventilated area, such 
as an attic, wall, ceiling, crawl space under a 
building or concealed space of a building.
W045
To reduce the risk of fire, DO NOT use plastic 
pipe or flexible plastic pipe to exhaust the 
dryer.
W041
WARNING
DESCRIPTION
KIT P/N
MAY BE 
OBTAINED 
LOCALLY
Exhaust Duct (4" Dia.)
Not Available
Yes
Flexible Metal Duct 
(4" Dia)
521P3
Yes
Weather Hoods, with 
hinged dampers (4")
Not Available
Yes
Directional Exhaust Kit
528P3
No
Tape
Not Available
Yes
DON'T
D356IE0B
D354IE0C
DO