Multi-dryer Installation
Exhaust Requirements
• The illustration below shows a typical example of a 
multiple dryer installation. Note how each dryer has its 
own exhaust system vented to the central exhaust duct.
IMPORTANT: Static pressure in the dryer’s exhaust 
duct should be no greater than that shown in the chart 
on Page 23. This can be measured with a manometer 
placed on the exhaust duct approximately 60.96 cm 
(two feet) from the dryer. See Page 23. All dryers 
connected to the main collector duct should be in 
operation when pressure is checked. 
Installing an exhaust system does not eliminate the 
necessity of cleaning the dryer lint filter before each load. 
The dryer interior and the complete exhaust system 
should be cleaned periodically by a qualified service 
person to remove any lint build-up.
IMPORTANT: DO NOT block the airflow at the 
bottom of the dryer’s front panel with laundry, rugs, 
etc. Blockage will decrease airflow through the dryer, 
thus reducing the efficiency of the dryer.
D164IE3B
METERED MODELS 
ILLUSTRATED
58786
BACKDRAFT DAMPER
(Available through your
local authorized parts source)
CLEAN OUT 
COVER MUST
BE PROVIDED
WEATHER HOOD
OR SWEEP ELBOW
(No cap or screen)
To reduce the risk of electric shock, 
disconnect the electrical service to the dryer 
before cleaning.
W043
WARNING