Electrolux w4250n-s Manuel D’Utilisation

Page de 140
35
6204
18
19
6204
6204
20
21
6204
*SERVICE*
01.10.00.00
SHOW COM.PORTAR
WEIGHT CALIBRATION
MEASURE WEIGHT
MEASURE UNBALANCE
DISPLAY TEST
EXIT
 
*WEIGHT CALIBRATION*
YES
18
19
*SERVICE*
01.11.00.00
WEIGHT CALIBRATION
MEASURE WEIGHT
MEASURE UNBALANCE
DISPLAY TEST
EXIT
*START WEIGHING*
YES
20
21
Program unit
WEIGHT CALIBRATION
Select the WEIGHT CALIBRATION row and
press the knob. 
•  Operate the machine with an empty drum.
•  After weight calibration, the weight deviation
will be shown in a hexadecimal format on the 
bottom line of the display.
•  The drum will go faster and slower a num-
ber of times during weight calibration. This 
is normal. Weight calibration will take a few 
minutes.
•  When exiting weight calibration after it is
complete, you will have the option of saving 
the calibration value.
•  The value for 0 calibration is taken on each
washing occasion and the weight value is 
adjusted automatically for any deviations.
NOTE! 
The drum must be empty during calibration.
Confirm that calibration is to be performed with 
YES or return to the previous menu with NO.
MEASURE WEIGHT
Select the MEASURE WEIGHT row and press 
the knob.
Put in a known weight. The same weight must 
be shown in the display once the weight has 
been measured.
Confirm that measurement is to be performed 
with YES or return to the previous menu with
NO.
This function is used to check that the machine 
is weighing correctly.