Table 9-4.  MX2800 Informational Events
AID
Notification 
Code
Condition 
Type
Service
Affecting
Location
Description
Recommended Action
REPT
EVT T1
101-128
EVT
BPV
NSA
NEND
Excessive DS1 Bipolar Viola-
tion
Make sure the line coding (B8ZS/AMI) is provisioned 
correctly for this DS1 facility. Check the DS1 facility entering 
the MX2800 for impairments which may cause line code 
violations.
101-128
EVT
AIS
NSA
FEND
DS1 Line AIS (LAIS)
Check the status of this DS1 signal toward the MX2800 at 
each DS1 device (for example, an intermediate device which 
sees LOS on the DS1 toward the MX2800 may transmit AIS 
toward the MX2800 in response).
101-128
EVT
AISUONE
S
NSA
FEND
DS1 Carrier AIS (CAIS)
If there are no DS3 or DS2 alarms reported, check the status of 
the DS1 facility entering the far-end M13 multiplexer. For 
example, if the far end M13 multiplexer detects LOS on the 
DS1 facility, it will send DS1 AIS over the DS3 toward the 
MX2800.
REPT
EVT T2
REPT
EVT T3
201-207
EVT
AIS
NSA
FEND
DS2 AIS
Check status of DS2 at the far-end M13 multiplexer.
302
(CTRL A)
EVT
AIS
NSA
FEND
DS3 Alarm Indication Signal
Check the status of the DS3 signal toward the MX2800 at each 
DS3 device. (For example, an intermediate device which sees 
LOS or LOF on the DS3 toward the MX2800 may transmit 
AIS toward the MX2800 in response.)
303
(CTRL B)
302
(CTRL A)
EVT
BPV
NSA
NEND
Excessive DS3 Bipolar Viola-
tion
Check DS3 facility entering the MX2800 for problems which 
may produce bipolar violations.
303
(CTRL B)
REPT
EVT
EQPT
401
(GENERAL)
EVT
WKSWPR
NSA
NEND
Protection Switch
If protection switch was not performed manually, check for 
other alarms indicating the failure which caused the switch.
401
(GENERAL)
EVT
ESW
NSA
NEND
Excessive Protection Switch
If protection switches were not performed manually, check for 
other alarms indicating the failure(s) which caused the 
switches.
REPT
EVT
EQPT
402
CTRL A
EVT
PROGFLT
NSA
NEND
Software 
Version 
Mismatch
Reset the reported card so the new software can take effect.
403
CTRL B