6.2.6
F6 -INITIAL ZERO RANGE
To enter this parameter, press the [Tare] key when “
F6
” is shown.
The display will show the current initial zero range.
Press the [PLU4] key to change the value and press [Tare] to accept the value.
NOTE: Only 10% is allowed for the AZ
plus scales.
6.2.7
F7 -RE-ZERO RANGE
To enter this parameter, press the [Tare] key when “
F7
” is shown.
The display will show the current re-zero range.
Press the [PLU4] key to change the value and press [Tare] to accept the value.
NOTE: Only 2% is allowed for the AZ
plus scales.
6.2.8
F8 -SUCCESSIVE TARE
To enter this parameter, press the [Tare] key when “
F8
” is shown.
The display will show if the successive tare is on or off.
Press the [PLU4] key to change the value.
Press [Tare] to accept the displayed value.
NOTE: Either option is allowed for the AZ
plus scales.