Planet Technology VC-201 Manuel D’Utilisation

Page de 32
2
5. Troubleshooting
SYMPTOM: 
VDSL  LNK  LED  does  not  lit  after  wire  is  connected  to  the 
VDSL port.
CHECKPOINT: 
1. Verify  the  length  of  the  wire  connected  between  two  VC-
201 is not more than 1.5km. Please also try to adjust the 
DIP switch or VC-201 to other SNR mode.
2. Please note you must use one VC-201 with CO mode and 
the  other  VC-201  with  CPE  mode,  connect  to  each  other 
to make it work.
SYMPTOM: 
TP LNK/ACT LED does not lit after cable is connected to the 
port.
CHECKPOINT:
1. Verify  you  are  using  the  Cat.5  or  better  cable  with  RJ-45 
connector to connect to the port.
2. If  your  device  (like  LAN  card)  supports  to  Auto-Negotia-
tion,  please  try  to  manual  set  at  a  fixed  speed  of  your 
device to solve this problem.
3. The converter and the connected device’s power are on or 
not.
4. The  port’s  cable  is  firmly  seated  in  its  connectors  in  the 
switch and in the associated device.