Metrologic Instruments MS1890 Manuel D’Utilisation

Page de 48
 
 
10 
I
NSTALLING THE 
S
CANNER TO THE 
H
OST 
S
YSTEM
 
 
IBM MS1890-11 
 
1.  Turn off the host device.  
 
2.  Plug the male 10-pin RJ45 end of the 
MVC cable into the 10-pin socket on 
the MS1890.  There will be an audible 
click when the connector lock 
engages. 
 
3.  Slide the protective cable boot up the 
cable, over the connector and onto 
the end of scanner handle. 
 
4.  Connect the other end of the MVC 
cable to the host device. 
 
5.  Turn on the host device. 
 
6.  The MS1890 will start to initialize.   
All LEDs (yellow, white, and blue) will 
light for approximately 2 seconds then 
start to alternately flash.  When the 
scanner has finished initializing the 
LEDs will stop flashing and the unit 
will beep 3 times indicating that the 
scanner is ready for use.  
 
 
 
 
 
 
 
 
Plugging the scanner into a port on the host system does not guarantee 
that scanned information will be communicated properly to the host 
system.  The scanner is shipped from the factory configured with default 
settings.  Please refer to the MetroSelect Single-Line Configuration 
Guide (
MLPN 
00-02544) or MetroSet2’s help files for instructions on 
changing the scanner’s configuration.  In addition, please check that the 
scanner and host system are using the same communication protocol.  
 
 
See page 6. 
 
Figure 8.