Metrologic Instruments MS1890 Manuel D’Utilisation

Page de 48
 
 
23
D
ESIGN 
S
PECIFICATIONS
 
   
 
MS1890
 
D
ESIGN 
S
PECIFICATIONS
 
E
LECTRICAL
 
 
Input Voltage:  5.0VDC  ± 0.25V 
Peak = 2 W  (Typical) 
Operating = 1.65 W (Typical) 
Power: 
Idle / Standby = 800 mW (Typical) 
Peak = 400 mA (Typical) 
Operation =
 
330 mA (Typical) 
Current: 
Idle / Standby = 160 mA (Typical) 
DC Transformer:  Class 2; 5.2VDC @ 1A 
For Regulatory Compliance information, see pages 36 - 38. 
E
NVIRONMENTAL
 
 
Operating = 0°C to 50° (32° to 122°F) 
Temperature: 
Storage = -40°C to 60°C (-40°F to 140°F) 
Humidity:  0% to 95% Relative Humidity, Non-Condensing 
Light Levels:  Up to 100,000 Lux (9,290 Footcandles)
 
 
Shock:  Designed to withstand 2 m (6.5 ft.) drops 
Contaminants:  Dust tight and protected against splashing water. 
Ventilation: None 
required 
IP Rating:  IP54 
 