PECIFICATIONS
 
 
 
 
IS4220
 
S
PECIFICATIONS
 
O
PERATIONAL
 
 
Light Source:  650 nm VLD  
Depth of Field:  12.7 mm to 203 mm (.5" to 8")  for .33 (13 mil) bar code 
Width of Scan Field:  28.6 mm (1.125”) @ face; 102 mm (4”) @ 76.2 mm (3”) 
Scan Speed:  52 scans lines per second 
Scan Pattern:  Single scan line 
Min Bar Width:  0.173 mm (6.8 mil) 
Decode Capability: 
Autodiscriminates all standard bar codes; for other 
symbologies call a Metrologic representative 
System Interfaces: 
RS232, Light Pen Emulation, PC Keyboard Wedge, Stand 
Alone Keyboard, USB (low speed) 
Print Contrast:  35% minimum reflectance difference 
Number of  
Characters Read: 
up to 80 data characters  (Maximum number will vary based 
on symbology and density) 
Roll, Pitch, Yaw:  42°, 68°, 52° 
Beeper Operation:  3 tones or no beep 
Indicators (LED):  red = laser on, ready to scan   green = good read, decoding 
M
ECHANICAL
 
 
Length x Width x Height:  70 mm x 49 mm x 24 mm (2.75" x 1.94” x 0.94”)  
Weight:  105 grams (3.7 oz.) 
Cable Termination:  Application Dependent 
E
LECTRICAL
 
 
 
Input Voltage:  5VDC ± 0.25V 
Power: 0.75 
Operating Current:  135 mA  
DC Transformers:  Class 2; 5VDC @ 300 mA 
Laser Class 2: 
EN 60825-1:1993+A1:1997+A2:2001 
EN 60825-1:1994+A11:1996+A2:2001 
EMC:
 
  FCC, ICES-003 & EN 55022 Class A 
E
NVIRONMENTAL
 
  
Operating Temperature:  -20°C to 50°C (-4°F to 122°F)  
Storage temperature:  -40°C to 70°C (-40°F to 158°F) 
Humidity:  5% to 95% relative humidity, non-condensing 
Light Levels:  Up to 4842 Lux (450 footcandles) 
Shock:  Designed to withstand 1.5 m (5’) drops 
Contaminants:  Sealed to resist airborne particulate contaminants 
Ventilation: None 
required 