DKS Enterprises 6100 Manuel D’Utilisation

Page de 42
6050-065-L-11-08
1
UL325 Class of Operation 
Model 6050 Class I Only ; Model 6100 Class I, II, III, IV 
Type of Gate 
Vehicular Swing Gates Only 
Horsepower 1/2 
HP 
Voltage / Phase 
115 VAC Single-Phase 
Current 
Model 6050 1/2 HP –  4.3 Amps @ 120V ; Model 6100 1/2 HP –  5.4 Amps @ 120V 
Max Gate Weight 
Model 6050 - 400 Lbs. ;  Model 6100 - 500 Lbs. 
Max Gate Length 
Model 6050 - 10 Ft. ; Model 6100 - 14 Ft. 
Cycles Per Hour 
Model 6050 - 10 Per Hour ; Model 6100 - 60 Per Hour 
Speed 
90° in approximately 12 seconds 
Entrapment Protection 
Primary - Inherent adjustable clutch (Type C) 
   
Secondary - Inherent entrapment sensing system (Type A) and provision  
 
   
 
for connection of a non-contact sensor (Type B1)
6050 / 6100 SPECIFICATIONS
Use this manual with the following models only:
6050-080, 6050-081, 6100-080, 6100-081, 6100-082*, 6100-083*.
*Optional Convenience Open System
DoorKing, Inc. reserves the right to make changes in the products described in this manual without notice and without obligation of DoorKing, Inc. to notify any 
persons of any such revisions or changes. Additionally, DoorKing, Inc. makes no representations or warranties with respect to this manual. This manual is 
copyrighted, all rights reserved. No portion of this manual may be copied, reproduced, translated, or reduced to any electronic medium without prior written 
consent from DoorKing, Inc.
This manual is for operators 
manufactured after June 30, 2008.
11”
27.75” with Convenience Open
23” Standard
Post Mount Kit
P/N 2600-674
Pad Mount Kit
P/N 2600-671
Dimensions are the same 
for the operator housings.
Arm Assembly
Arm Assembly
Distance can vary.
6” minimum.
10.5”
13.5”
6.75”
6.25”
7.25”
6.75”
2.25”
18”
6”
3”
3”
11”
Note: 6100’s with Convenience Open:
Output shaft is offset 1” from center.
9.5”