CLT- & CLX-2IND/4IND 
 
Terminal Block & Module Locations in Single-wide Enclosure 
(CLT/CLX-4IND shown) 
Functional Summary 
TERMINAL BLOCK
(LEFT)
MODULE
GROUNDING 
TERMINAL BLOCK
 
The CLT/CLX-2IND is a 2-inductor terminal block and 
module kit while the CLT/CLX-4IND is a 4-inductor 
terminal block and module kit. Inductor modules are 
typically used to reduce hum from incandescent lamps 
that are connected to dimmer modules in a Crestron 
lighting system. These kits can be mounted in any 
Crestron Automation Enclosure (CAEN-Series 
Enclosures). The terminal block is for connecting wires 
into and out of the inductor module. The inductor is wired 
in series between the output of the dimmer module and 
the load. The maximum load for any inductor in the 
module is 16 amps.  
Each of these Terminal Block and Module kits is 
considered single entities and must be used together. The 
terminal blocks (CLT-2IND and/or CLT-4IND) are 
shipped separately from their respective modules  
(CLX-2IND and CLX-4IND) to permit termination of the 
field wiring to the terminal block prior to installation of 
the module, as described in this guide.  
 
Installation 
Terminal Block & Module Locations in Double-wide 
Enclosure (CLT/CLX-4IND shown) 
The terminal block and module must be mounted into a 
Crestron Automation Enclosure by a licensed electrician, 
in accordance with all national and local codes.  
TERMINAL BLOCK
(LEFT)
MODULES
TERMINAL BLOCK
(RIGHT)
GROUNDING 
TERMINAL 
BLOCKS
 
CAUTION:  This equipment is for indoor use only. 
Mount in a well-ventilated area. The ambient 
temperature must be 32
°F to 104°F (0°C to 40°C). 
The relative humidity must be 10% to 90% (non-
condensing).  
Terminal blocks are installed along the left side of single-
wide enclosures and along the outside edges (left and 
right sides) of double-wide enclosures. Modules are 
installed along the right side of single-wide enclosures 
and side-by-side in the center of double-wide enclosures. 
When installing modules and terminal blocks in a double-
wide enclosure, be sure to invert units on the right side so 
that they can be properly wired. Refer to the illustrations 
shown in the next column when considering the location 
of terminal blocks and modules within an enclosure.  
NOTE:  Inductor modules and terminal blocks 
should be installed above the dimmer modules, 
towards the top of the CAEN enclosure. 
 
Crestron Electronics, Inc.
 
Installation Guide – DOC. 6315
 
15 Volvo Drive   Rockleigh, NJ 07647
 