6.2 
Using Discrete IR 
Codes
The DHD Controller accepts commands in the form of IR signals that conform to the 
Phillips RC5 protocol. Each DHD Controller remote control button has an RC5 control 
code associated with it. 
You can use these codes to program a third-party, “universal” remote control unit to work 
with the DHD Controller. These third-party products usually come with a computer 
software application for this purpose. For more information, consult the documentation 
provided with the remote control unit. 
IR Command Protocol
The IR control codes have the following characteristics:
• Each code consists of 14 bits:
• Two (2) start bits (always 1);
• A toggle bit. This bit is inverted every time a key is released and pressed again. This 
allows the DHD Controller to distinguish between a button that remains down or is 
pressed repeatedly.
• Five (5) address bits. The default address is 17 (binary 10001). To change it, select 
Remote Control from the Service menu and follow the steps given on page 52
• Six (6) data bits
• The carrier frequency is 36 kHz, with the modulated pulses having a 25% duty cycle. 
• Commands are sent at a maximum rate of 9 Hz.
For example, here is the RC5 control code for the ON button on the DHD Controller 
remote control unit (assuming the default address is used):  
With Toggle Bit = 0
Hex
3
4
4
1
Binary
1
1
0
1
0
0
0
1
0
0
0
0
0
1
With Toggle Bit = 1
Hex
3
C
4
1
Binary
1
1
1
1
0
0
0
1
0
0
0
0
0
1
Function
Start 
Bits
Toggle 
Bit
Address
Command