Lifebreath 94-EXCHANGER Manuel D’Utilisation
5
•
Atleast
3'(1
m)away
fromthe
cornerof
thebuilding*
•
Atleast
3’away
fromgas
meter,electric
meteror
a
walkwaywhere
fogor
icecould
createa
hazard*
•
Notinto
agarage,
workshopor
otherunheated
space
Wheninstalling
theweather
hood,its
outsideperimeter
mustbe
sealedwith
exteriorcaulking.
*Local
codemay
requiregreater
distances.
IntakeWeather
HoodRequirements
•
Shouldbe
locatedupstream
(ifthere
areprevailing
winds)from
theexhaust
outlet
•
Atleast
6'(2
m)from
theexhaust
weatherhood
*
•
Atleast
6'(2
m)away
fromdryer
ventsand
airhandler
exhaust(medium
orhigh
efficiencyfurnaces)*
•
Aminimum
ofat
least6'
(2m)
fromdriveways,
oilfill
pipes,gas
meters,or
garbagecontainers,
swimming
pools*
•
Atleast
18"(457mm)
abovethe
ground,or
abovethe
depthof
expectedsnow
accumulation*
•
Atleast
3'(1
m)from
theinside/outside
cornerof
the
building*
•
Donot
locatein
agarage,
atticor
crawlspace
*Local
codemay
requiregreater
distances.
36" (1m)
recommended min.
36" (1m)
recommended min.
6' (2m)
recommended min.
18" (460mm) min.
18" (460mm) min.
OUTSIDE CORNER
INTAKE
EXHAUST
INSIDE CORNER
Weatherhood arrang
ement - requires a minimum of 6'
(2m) separation and a minimum of 18" (460mm)
clearance abo
ve the higher of the grade or anticipated
snow
level.
CAUTION
Weather
HoodClearances
Suspendingthe
Unitusing
the
Pro
videdHanging
Straps
Unit must be installed le
vel to ensure proper
condensate drainag
e. Due to the br
oad range of
installation and operational conditions,
consideration must be given f
or the possibility
of condensation forming on the unit or
connecting ducting. Objects belo
w the
installation may be e
xposed to condensate.
CAUTION
1.ThermalCollarslidesovergalvanized
sleeveofWeatherhood.
2.FastenThermalCollartoBelt.
3.SlidetheInsulatedFlexibleDuctingover
theWeatherhood'sgalvanizedsleeveand
fastenittotheThermalCollar.
4.Hoodishingedtoallowforeasyaccess
forcleaningofbirdscreen.
1/4"(6mm)SCREEN
(frontview)
EXTERIOR
WALL
SCREEN
(sideview)
COLLARISSUPPLIED T
O
ENSUREV
APOURBARRIER
IS100%SEALED T
O
WALLPLA
TE
12"galvaniz
ed
pipesupplied
Weatherhood
Installation