Desa td101a, td103a, td109a, td111a Manuel D’Utilisation

Page de 40
www.desatech.com
3
1749-01A
Clothing  or  other  flammable 
materials  should  not  be  hung 
from the heater, or placed on or 
near heater.
Installation  and  repair  should 
be done by a qualified service
person.  The  heater  should  be 
inspected before use and at least 
annually by a qualified service
person. More frequent cleaning 
may be required as necessary. 
It  is  imperative  that  control 
compartments,  burners,  and 
circulating air passageways of 
the heater be kept clean.
 CAUTION: The gas pressure 
regulator provided with this ap-
pliance must be used. This regu-
lator is set for an output pressure 
of 11" W.C. (0.4 P.S.I.).
1.  Install and use heater with care. Follow 
all local ordinances and codes. In the ab-
sence of local ordinances and codes, refer 
to the Standard for Storage and Handling 
of Liquefied Petroleum Gas, ANSI/NFPA 
58,  CAN/-B149  Installation  CODE
. This 
instructs on the safe storage and handling 
of propane/LP gases.
.  Use only propane/LP gas set up for vapor 
withdrawal in a 0 lb. cylinder. Cylinder must 
be constructed and marked in accordance 
with specifications for propane/LP cylinders 
of the U.S. Department of Transportation 
(DOT). The cylinder must be provided with 
a shutoff valve terminating in a propane/LP 
supply cylinder valve outlet. The valve must 
have external threads and marked “Use with 
Type 1” and a safety relief device having a 
direct communication with the vapor space 
of the cylinder. The cylinder used must in-
clude a collar to protect the cylinder valve.
3.  Keep appliance area clear and free from 
combustible  materials,  gasoline,  paint 
thinner, and other flammable vapors and 
liquids. Dust is combustible. Do not use 
heater in areas with high dust content.
SAFETy
Continued
Figure 1 - Clearances from Combustibles
4.  Spillage  of  combustible  liquids  into  the 
flame could cause a fire.
5.  Do not place combustible table cloths on 
heater table. If table cloth is used, do not 
allow any part of cloth to hang over edge 
of table into heat outlet area.
6.  Table becomes warm in operation.
7.  Minimum heater clearances from perma-
nent combustible construction:
 
Front, Back and sides 6" (15. cm), Top 
36" (0.91 m) (see Figure 1).
8.  Before each use, check heater for leaks. 
Never use an open flame to check for a 
leak. Apply a mixture of liquid soap and 
water to all joints. Bubbles forming show 
a leak. Correct all leaks at once.
9.  Keep propane/LP cylinder below 100° F 
(38° C).
10. Use  only  the  hose  and  factory  preset 
regulator provided with the heater. Do not 
adjust regulator as gas leaks may occur.
11. Locate  hose  properly,  keeping  it  out  of 
pathways where people may trip over it or 
in areas where the hose may be subjected 
to accidental damage. Keep hose away 
from burner on inside of heater.
1. Check  hose  before  each  use  of  heater. 
Disconnect  hose  with  9/16"  wrench. 
Check for tears and abrasions in hose and 
on regulator. If highly worn or cut, replace 
with hose specified by manufacturer be-
fore using heater.
13. Do not alter heater. Keep heater in its origi-
nal state. Do not use heater if altered.
14. Locate heater on stable and level surface.
15. Do not operate heater while sleeping or 
leave heater unattended.
6"
(15. cm)
36" (0.91 m)
6"
(15. cm)
6"
(15. cm)
6"
(15. cm)