crimestopper-security-pro rs-7 Manuel D’Utilisation

Page de 28
 
15 
DIESEL GLOW PLUG DELAY 
 
This feature provides a solution for diesel vehicles without having to connect to the Glow Plug-Wait to Start Circuit. This 
may be needed for various reasons.  If your vehicle does not have a viable  Wait to Start Circuit , or you cannot locate and 
identify the circuit, then change your system to Diesel Glow Plug Delay mode.  You can choose from a selection of  pre-
cranking  delay times.  Once this mode is activated, the system will NO LONGER monitor the PINK glow plug input wire 
and will use a delay setting chosen by the installer in the option chart. 
 
 
NOTES: This feature is OFF by default and must be programmed before use.  Once this feature is turned ON, the Pink 
Glow plug input wire is not used.  The Remote start unit will always wait the programmed time before cranking EVEN IF 
the glow plug warms up first.  There are 3 different Delay times available for use: 10, 20, or 30 seconds.  SEE OPTION 
PROGRAMMING CHART on Pages 16-17. 
 
 
HOW TO USE THIS FEATURE: 
1.  See the Option Programming section on Pages 17-18 and change Option #19 from Monitor Glow Plug Light to one 
of the delayed time values. (Default setting is to always monitor the PINK Glow Plug input wire.) 
2.  Once this option has changed, the system will wait for the selected time before cranking. 
 
 
 
OPTION PROGRAMMING 
 
This CoolStart unit has over 23 programmable control options to customize the system for various operating features and 
installer preferences.  Examine the chart on the pages 16-17 along with reading the descriptions that follow on pages 18-
20. You may change one option at a time, or program multiple options in one session.  If you start with the lowest option 
and continue on to higher options, you do not need to repeat steps #1-3 each time.  For example, you can change Option 
#2 to “ON”, then you can continue pressing the program button to get to a higher number option and change it as well.  
You can only go from low to higher options numbers in one session. 
 
 
 
 
 
 
OPTION PROGRAMMING CHART BEGINS ON NEXT PAGE