Q-Logic 8200 Manuel D’Utilisation

Page de 130
1–Product Overview
Adapter Specifications
1-4
SN0054671-00  A
Environmental Specifications
Table 1-1. Environmental Specifications
Condition
Operating
Non-Operating
Temperature Ranges 
(for Altitude=900 m or 2952.75 ft) 
10°C to 55°C
 a
(50°F to 131°F)
a
200LFM is required to operate at this temperature.
–40°C to 65°C
(–40°C to 149°F)
Temperature Ranges
(for Altitude >900 m or 2952.75 ft) 
10°C to n°C
 b
 
(50°F to n°F
 c
)
b
Use the following formulas to calculate the maximum operating temperature (in °C) for a specific 
altitude. Use the first formula if the altitude is stated in meters and the second formula if the altitude 
is stated in feet.
c
Use the following formulas to calculate the maximum operating temperature (in °F) for a specific 
altitude. Use the first formula if the altitude is stated in meters and the second formula if the altitude 
is stated in feet.
–40°C to 65°C
(–40°F to 149°F)
Temperature Gradient Maximum 
per 60 Min. 
10°C
 20°C
Humidity Percent Ranges—Non-
condensing 
20% to 80%
(Max Wet bulb temper-
ature= 29°C)
 d
d
Maximum corrosive contaminant levels measured at =50% relative humidity; see Table 3 in 
ISA-71.04-1985.
 5% to 95%
(Max Wet bulb tempera-
ture= 38°C)
d
Humidity Gradient Maximum 
per 60 Min.
10%
10%
Altitude Ranges—Low Limits 
–15.2m (–50 ft)
–15.2m (–50 ft)
Altitude Ranges—High Limits 
3,048m (10,000 ft)
 10,668m (35,000 ft)
Airborne Contaminants—ISA-71 
Level 
G1
d
 G1
d