Honeywell F500 Manuel D’Utilisation

Page de 8
F500 WHOLE HOUSE/ LIGHT COMMERCIAL HEPA FILTRATION SYSTEM
68-0263-2
6
STARTUP AND CHECKOUT
After the Whole House/Light Commercial HEPA System is 
installed, with the ductwork in place and the unit plugged into 
a correctly grounded outlet:
1.
Be sure filters are installed in correct locations and ori-
ented correctly. (Note the air flow direction arrows on 
the prefilter and the HEPA filter.)
2.
Turn the On/Off switch to the On position.
3.
If interconnected to the HVAC system blower, turn on 
the system blower.
4.
Verify that the Whole House/Light Commercial HEPA 
Air Cleaner turned on.
TROUBLESHOOTING 
See Table 3 for troubleshooting guide.
Table 3. Troubleshooting Guide.
Symptom
Cause Solution
Poor airflow
Filters plugged
Remove and replace filter(s). 
Maintain filters at regular intervals.
Poor power supply at the site.
Have electrician check supply voltage at outlet.
Ductwork is restricting airflow.
Check duct installation.
AIRWATCH beeping 
and/or flashing
Battery or filter needs replacing.
Observe which LCD is flashing. 
Replace the battery or filter, as indicated.