4. VIDEO SOUNDER OPERATION 
 
 
 
4-24
Alarm messages 
The table below shows the sounder alarm messages and their meanings 
Sounder alarm messages and their meanings 
Message Meaning 
DEPTH ALARM! 
Bottom alarm violated. 
FISH ALARM! 
Fish alarm violated. 
TEMPERATURE ALARM! 
Water temperature alarm violated. 
 
 
4.13  Water Temperature Graph 
The water temperature graph (appropriate sensor required) plots water 
temperature on the sounder display. (See the figure on page 4-3.) It can be 
turned on or off as below. 
 
1.  Press the [MENU] key to open the menu. 
2.  Press the SOUNDER MENU soft key. 
3.  Select TEMPERATURE GRAPH and press the EDIT soft key. 
4.  Select OFF (default setting) or ON as appropriate. 
5.  Press the ENTER soft key. 
6.  Press the [MENU] key to close the menu. 
 
 
4.14  Changing Pulse Repetition Rate 
Pulse repetition rate can be changed. Normally, the highest rate (20) is used. 
When in shallow waters, second reflection echoes may appear between surface 
and actual bottom echo. In this case lower the PRR level. The option “SPD 
SENSING PRR” means the ship’s speed dependent mode, where the PRR 
changes automatically with ship’s speed (required speed input.) For further 
information about the ship’s speed dependent mode, see page 4-17.   
 
1.  Press the [MENU] key to open the menu. 
2.  Press the SOUNDER MENU soft key. 
3.  Press the cursor pad to select PRR LEVEL. 
4.  Press the EDIT soft key to open the setting window. 
5.  Use the cursor pad to select he rate for repetition. 
6.  Press the ENTER soft key followed by the [MENU] key to close the menu. 
 
Too small setting reduces the number of pulse repetition. This may cause a 
problem to search fish schools. Select “20” unless multistage reflections appear 
on the display.