Furuno gd-1700c Manuel D’Utilisation

Page de 249
1. OPERATIONAL 
OVERVIEW 
 
 
 1-7
1.3 
Turning the Unit On/Off 
Press the [POWER/BRILL] key to turn the unit on. A beep sounds and the 
equipment proceeds in the sequence shown below, displaying the production 
information screen, startup test results and the chart usage disclaimer. The 
startup test checks the ROM, RAM, internal battery and backup data for proper 
operation, displaying the results for each as OK or NG (No Good). If NG appears 
an appropriate message appears on the screen. For any NG, try to press any 
key to go to the chart disclaimer screen, then perform the diagnostic test 
referring to the paragraph “7.5 Diagnostics.” 
GD-1700(C) PLOTTER
     STATION NAME:
      PLOTTER*
FURUNO ELECTRIC CO., LTD.
CHARTS AVAILABLE
LICENSE NO.
                 STARTUP TEST
ROM
OK
RAM
OK
BACKUP DATA
OK
INTERNAL BATTERY
OK
è
è
Product information                            Startup test                                Chart disclaimer
Host Name
Chart List
NO NATIONAL HYDROGRAPHIC
OFFICE HAS VERIFIED THE
INFORMATION IN THIS
COASTLINE DATA CARD AND NONE
ACCEPT LIABILITY FOR THE 
ACCURACY OF REPRODUCTION OR
ANY MODIFICATIONS MADE 
THEREAFTER. THIS PRODUCT WITH
THIS COASTLINE DATA CARD
DOES NOT REPLACE THE 
REQUIREMENT TO USE THE
APPROPRIATE PRODUCTS FOR
NAVIGATION ACCORDING TO
NATIONAL AND INTERNATIONAL
REGULATIONS.
PROGRAM No.  (See above) 
* = Name determined at installation.
XX= Program Version No. 
GD-1700
C-MAP: 03591700XX
NAVIONICS: 03591710XX
GD-1710C 
C-MAP: 03591960XX
NAVIONICS: 03591970XX 
GD-1700C 
C-MAP: 03591720XX
NAVIONICS: 03591730XX 
 
Startup sequence 
You may press any key at the chart disclaimer screen to show the last-used 
display, or wait several seconds to let the equipment do it for you. For start up 
with the radar display,
 the magnetron takes from one minute to two minutes 
and thirty seconds (depending or radar model) to warm up before the radar can 
be operated. The time remaining for warm up of the magnetron is counted down 
at the center of the display. 
 
To turn the unit off, press and hold down the [POWER/BRILL] key until the 
display goes dark (about 3 sec.). To protect the LCD attach the hard cover. Note 
that the network sounder is turned off approx. three minutes after turning off the 
power. 
 
Note: The first time you turn on the power (or any time the power is applied after 
a memory reset), you are asked if you want to start the simulation mode, 
which provides simulated operation of the equipment. Push the [ENTER] 
knob to start the simulation mode, or press the [CLEAR] key to start 
normal operation. For details about the simulation mode, see the 
paragraph “1.10 Simulation Display.”