Datalogic Scanning gryphon d432e Manuel D’Utilisation

Page de 164
USING GRYPHON™ D432/D432E 
5
 
normal operation. To capture another image you must read another Capture Image 
Code of the same or a different Preset Configuration. 
 
You can use the aiming system to position the reader from the object (ensure the 
reader is about centered over the target). Adjust the distance at which you are 
holding the reader (see Figure 2). 
 
If the RS232 interface has been selected, the image will be transferred to the host 
PC via XMODEM_1K protocol. 
 
 
NOTE 
Image capturing is not available in Wedge and USB Keyboard 
Emulation interfaces and is not compatible with Autoscanning nor 
when the Software trigger type is selected. 
 
Up to four different and independent Image Presets can be defined (see page 74). 
For each Image Preset you may set up to three Basic Configuration Parameters, and 
up to five Advanced Configuration Parameters. Therefore an image is processed 
before being sent to the Host, according to a preset group of parameters. 
 
 
3.3.1 
Basic Configuration Parameters 
 
The Image file formats supported are: BMP, TIFF
JPEG (default). 
 
Two resolution options are available: VGA Resolution (640 x 480 pixels) (default), 
and CIF Resolution (320 x 240 pixels). The lower resolution setting yields smaller file 
sizes, so the transfer time decreases. 
 
For JPEG images it is possible to define the Image Quality level to address tradeoff 
between image file size and quality.