HOW TO CORRECT PROBLEMS IN THE MACHINE
PROBLEM 
 
 
        CAUSE   
 
                 ACTION
nsuffi cient water onto the brushes
The machine does not clean  
satisfactorily
The squeegee does not dry the fl oor
The vacuum motor does not function 
The machine does not start
The brush motors do not work 
WARNING: To avoid damage to the fl oor, the 
motor starts only when the machine is tra-
versing.
The solution fl ow is not set
There is no water in the solution tank.
The solution fi lter is dirty.
A circuit breaker has tripped.
Insuffi cient fl ow. 
 
 
The brushes are worn.
Need to use a different kind of brush/pad
The squeegee is dirty.
Recovery drain hose is not closed.
The suction hoses need to be cleaned. 
The squeegee blades are worn.
The recovery tank is full.
The squeegee up/down switch in not in the low or 
middle position.
The operator is not properly seated.
The key is not in the “ON position”.
The charger is still connected.
The batteries are not charged or not connected 
properly.
The circuit breaker has tripped.
The brush head unit is not down.
The batteries are not charged or not connected 
properly.
Poor electrical connection at the brush head unit.
Make sure the solution fl ow is set.
Fill the solution tank.
Clean the solution fi lter.
Reset the circuit breaker.
Increase fl ow with solution switch.
Check the brushes and replace if necessary.
(the brushes have to be replaced when the 
bristles reach approximately .59 inches (15mm 
height.)
Use a different kind of brush.  For cleaning opera-
tions on fl oors where the dirt proves to be par-
ticularly resistant, we recommend using special 
brushes.  See Accessories page.
Clean the squeegee.
Close the drain plug.
Clean the vacuum hoses.  See “Routine Mainte-
nance” section.
Replace/ or rotate  the squeegee blades.  See 
“Routine Maintenance” section.
Drain recovery tank.
Put the squeegee in the low or middle position or 
reprogram “one touch”.
The operator must be properly seated in the driv-
ing position.
Turn the key to the “ON” position.
Remove the A/C cord from the wall.
Check to make sure the batteries are connected 
properly and charge if necessary.
Reset the circuit breaker.
Put the brush head unit down.
Check to make sure the batteries are connected 
properly and charge if necessary.
Connect the electrical connection at the brush 
head unit.