kb-electronics kbmg Manuel D’Utilisation

Page de 19
“The Right Control for Your Application.”
12095 NW 39 Street, Coral Springs, FL 33065-2516
KB Electronics, Inc.
Telephone: 954-346-4900; Fax: 954-346-3377
6LJQDO,VRODWRU6,0*3DUW1R,QVWDOODWLRQDQG:LULQJ,QVWUXFWLRQV
IRU0RGHO.%0*ZLWK3LHFH)LQJHU6DIH&RYHU
(A40138) - Rev. B00 - 9/1/2004 - Z3031B00
Page 1 of 2
This document is supplied with Model KBMG only.
 Warning!  Before installing the SIMG onto the KBMG, the AC power must be disconnected.
The following Installation and Wiring instructions are to be used as a supplement to the KBMG Installation and Operating Instructions Manual
(Part  No.  A40263).    Refer  to  the  SIMG  Installation  and  Operating  Instructions  Manual  (Part  No.  A40269)  for  specific  and  external  signal
following connections. See Figures 1 - 5, on page 2.
Tools required for installation: small flat blade screwdriver, long nose pliers, cutters.
Notes:  1.  To  install  the  SIMG,  be  sure  the  Top  Panel  of  the  KBMG  2-Piece  Finger-Safe  Cover  (FSC)  is  not  installed.    2.  All  trimpots  and
jumpers, on the KBMG, must be set before installing the SIMG.
1
Preparing the KBMG Prior to Installing the SIMG - See Figure 1.
1.1 Insert the flat blade screwdriver between the KBMG PC Board and Terminal Block TB1 and gently pry  it  off.   Discard the Terminal
Block.
Note: When prying off the Terminal Block, care should be taken to not scratch circuit traces that are on the PC Board surface.
1.2 Using a flat blade (or Phillips) screwdriver, remove the screw from the KBMG FSC.  Retain this screw for use in Section 3.3, below.
1.3 Using long nose pliers, remove and discard the Terminal Boots that are factory installed on Terminals "F-" and "F+" on the KBMG.
2
Preparing the SIMG for Installation onto the KBMG - See Figure 2.
Note: If the SIMG does not contain a Ring Lug and Cable Tie, proceed to paragraph 3 below.
2.1 Using long nose pliers, carefully uncurl the Ring Lug off the Cable Assembly.
2.2 Using cutters, carefully remove the Cable Tie from the SIMG.
2.3 Discard the Ring Lug and Cable Tie.
3
Installing the SIMG onto the KBMG - See Figure 3.
3.1 Align and gently push the Terminal Block on the SIMG onto the Terminal Block Header on the KBMG.
3.2 Align the (3) Holes on the SIMG with the (3) Snap Posts on the KBMG FSC.  Gently press the SIMG Board onto the (3) Snap Posts.
Apply pressure at each Snap Post.
3.3 Install  the  Screw,  that  was  removed  in  Section  1.2,    and  gently  tighten  it  to  secure  the  SIMG  onto  the  KBMG  FSC.    Do  not
overtighten.
4
Wiring the SIMG After Installed onto the KBMG - See Figures 4 and 5.
Note:  On  older  SIMG  models,  the  Brown  and  Yellow Wires  must  be crisscrossed,  as  shown  in  Figure  3.    On  newer  SIMG  models,  the
Brown and Yellow Wires are not crisscrossed.
4.1 Carefully insert the Cable Assembly through the Retainer Clip on the KBMG FSC.
4.2 Connect the Brown Wire (larger terminal) to Terminal F- on the KBMG.
4.3 Connect the Yellow Wire (smaller terminal) to Terminal F+ on the KBMG.
5
Installing the SIMG Finger-Safe Cover - See Figure 3.
Align the (4) Snap Tabs on the SIMG FSC with the (4) slots on the KBMG  FSC.   The  Cable  Shroud must  be  positioned  over  the  Cable
Assembly (Brown and Yellow Wires).  Apply pressure to snap the cover into position.
Note: Be sure that the Cable Assembly is centered in the Retaining Clip so the wires are not damaged by the Cable Shroud.
The SIMG Installation is now complete.