IBM as-400 Manuel D’Utilisation
The default value for each bit is underlined in the Bit Value column.
To configure the AS/400 to a 3684 retail controller, use the following table.
LINECON Bit
Bit Value
AS/400 Parameter and
Value
Notes
0
0
None
Enabled at initial microprogram load (IML). There is no
equivalent parameter for the AS/400 system. Specify
equivalent parameter for the AS/400 system. Specify
0
to indicate that the controller is enabled at IML, or
1 to
indicate that the controller is not enabled at IML.
1
None
1
0
NRZI(*NO)
Specifies NRZI data encoding with leading pads (
1) or
non-NRZI without leading pads (
0).
1
NRZI(*YES)
2 and 3
00
SWITCHED (*YES) and
CNN(*SWTPP)
CNN(*SWTPP)
Bit 2: Specify 1 is using nonswitched communications,
or 0 if using switched communications. If switched, the
SENDID parameter must also be specified.
or 0 if using switched communications. If switched, the
SENDID parameter must also be specified.
Bit 3: Specify 1 if using a multipoint communications
protocol, or 0 if not. 01 is not a valid combination for
these bits.
protocol, or 0 if not. 01 is not a valid combination for
these bits.
01
Not valid
10
SWITCHED(*NO) and
CNN(*NONSWTPP)
CNN(*NONSWTPP)
11
SWITCHED(*NO) and
CNN(*MP)
CNN(*MP)
4
0
SNBU(*NO)
Switched network backup.
1
SNBU(*YES)
5
0
MODEMRATE(*FULL)
Data rate select speed.
1
MODEMRATE(*HALF)
6
0
DUPLEX(*HALF)
Data carrier setting.
1
DUPLEX(*FULL)
7
0
None
Answer tone generation. There is no equivalent
parameter for the AS/400 system. Specify
parameter for the AS/400 system. Specify
0 to indicate
that the controller generates the answer tone, or
1 to
indicate that the answer tone is omitted.
1
None
Matching AS/400 parameters for 4680/4690 LINE parameter
You must coordinate parameters between the AS/400 and the 4680 or 4690 retail controller. The following
table lists those parameters. The 4680 controller requires configuration of the SDLC/SNA LINE parameter.
table lists those parameters. The 4680 controller requires configuration of the SDLC/SNA LINE parameter.
AS/400 parameters are listed in alphabetical order; the commands on which the parameters are specified
are included in the rightmost column of the table.
are included in the rightmost column of the table.
For more information about configuring the 4680, see the IBM 4680 Store System: Programming Guide.
To configure the AS/400 to a 4680/4690 controller:
v See “Examples: Connecting AS/400 to a 4690 retail controller” on page 75 for an example of an AS/400
v See “Examples: Connecting AS/400 to a 4690 retail controller” on page 75 for an example of an AS/400
connecting to a 4690 retail controller.
v Use the following table to connect an AS/400 to a 4690 retail controller.
72