DIAGNOSTICS 
3.1 
DishDrawer™ Diagnostics 
Dishwasher Diagnostics can only be entered in Power Off mode, i.e. when 
there is no display on the LCD or the badge LED’s are off.  Diagnostics is 
entered by holding the KEYLOCK  and START/PAUSE buttons 
simultaneously for 5 seconds.  Ensure that KEYLOCK is pressed first. 
 
There are currently four levels of diagnostics.  To move to the next level, 
press POWER.  To enter a level, press START/PAUSE.  Once a level has 
been entered, pressing POWER will exit diagnostics completely.  If no level is 
entered, then the display will cycle through the four levels and exit after the 
last.  On entering diagnostic mode, the first level is the Display/Download 
Mode. 
3.2 
Display/Download Mode 
In this mode, all LED’s and LCD segments (except keylock) are illuminated. 
3.3 
Optical LED Download/Fault Display 
An optical data download is available here to download all EE data to a PC or 
Palm PC via the lower tub-home sensor light pipe.  Hold the reader pen over 
the lower tub-home sensor light pipe and press START/PAUSE to initiate the 
download.  A short beep indicates the start and finish of download. 
 
The last two faults are displayed on the LCD (secondary control panel LEDs 
for integrated and flat door models) during the optical download.  The Current 
Fault code is displayed first followed by the Previous Fault Code.  To read the 
3.4 
Clearing Fault Logs 
To clear the current fault code, press the KEYLOCK button until a beep is 
sounded.  This action moves the current fault into the previous fault while 
clearing the current fault.  To clear the previous fault code, press KEYLOCK 
once more until the beep is sounded. 
Warning:  
Once a fault code has been cleared, it is permanently removed 
from memory and cannot be recovered. 
 
Press POWER to advance to the next level.